52
ENGLISH
Note:
These problems can be considered normal if the coff ee blend has been
changed or if the machine has just been installed. In this case wait until the
machine performs a self-adjusting operation as described in the "Gaggia
Adapting System" chapter.
Machine actions
Causes
Solutions
The machine grinds the coff ee
beans but no coff ee comes
out.
(See note)
There is no water.
Fill the water tank and prime the
circuit (see the "Using the Machine for
the First Time" chapter).
The brew group is dirty.
Clean the brew group (see the
"Weekly Cleaning of the Brew Group"
chapter).
The circuit is not primed.
Prime the circuit (see the "Using the
Machine for the First Time" chapter).
This might occur when the ma-
chine is automatically adjusting
the dose.
Brew a few cups of coff ee as
described in the “Gaggia Adapting
System” chapter.
The dispensing spout is dirty.
Clean the dispensing spout.
Coff ee is too weak.
(See note)
This might occur when the ma-
chine is automatically adjusting
the dose.
Brew a few cups of coff ee as
described in the “Gaggia Adapting
System” chapter.
Coff ee is brewed slowly.
(See note)
The coff ee grind is too fi ne.
Change coff ee blend or adjust the
grind as explained in the “Adjusting
the Ceramic Coff ee Grinder” chapter.
The circuit is not primed.
Prime the circuit (see the "Using the
Machine for the First Time" chapter).
The brew group is dirty.
Clean the brew group ("Weekly Clean-
ing of the Brew Group" chapter).
Coff ee leaks out of the dis-
pensing spout.
The dispensing spout is clogged.
Clean the dispensing spout and its
holes.
Milk does not froth.
The Automatic Milk Frother is
inserted too deep. No milk is being
suctioned.
Leave the Automatic Milk Frother to
cool down. Move it slightly down-
wards. Reposition it in its correct seat.
Frothed milk is too cold.
The cups are cold.
Preheat the cups with hot water.