background image

Pub. 42004-387G 

Model 4512-001, 4512-001FR, 4514-001, and 4514-001FR 6-Channel Radios 

Page 9 of 19 

f:\standard ioms - current release\42004 instr. manuals\42004-387g.doc 
02/15 

Safe Handling of CMOS Integrated Circuit Devices 

Many of the integrated circuit devices used in communications equipment are of the Complementary 
Metal Oxide Semiconductor (CMOS) type.  Because of their high open circuit impedance, CMOS 
integrated circuits are vulnerable to damage from static charges.  Care must be taken handling, shipping, 
and servicing them and the assemblies in which they are used. 

Even though protection devices are provided in CMOS integrated circuit inputs, the protection is effective 
only against overvoltage in the hundreds of volts range such as is encountered in an operating system.  In 
a system, circuit elements distribute static charges and load the CMOS circuits, decreasing the chance of 
damage.  However, CMOS circuits can be damaged by improper handling of the modules, even in a 
system. 

To avoid damage to circuits, observe the following handling, shipping, and servicing precautions: 

1.

 

Prior to and while servicing a circuit module, particularly after moving within the service area, 
momentarily touch both hands to a bare metal, earth-grounded surface.  This will discharge any static 
charge that may have accumulated on the person doing the servicing. 

N

OTE

:

  Wearing a conductive wrist strap will minimize static build-up during servicing. 

2.

 

Whenever possible, avoid touching any electrically conductive parts of the circuit module with your 
hands. 

3.

 

Power down the unit before installing or removing the circuit module. 

4.

 

When servicing a circuit module, avoid carpeted areas, dry environments, and certain types of 
clothing (silk, nylon, etc.) because they contribute to static build-up.  Similarly, disconnect the test 
probe prior to removing the ground lead. 

5.

 

All electrically powered test equipment should be grounded.  Apply the ground lead from the test 
equipment to the circuit module before connecting the test probe. 

6.

 

If a circuit module is removed from the system, it is desirable to lay it on a conductive surface (such 
as a sheet of aluminum foil) that is connected to ground through 100k of resistance. 

7.

 

When soldering, be sure the soldering iron is grounded with a grounded tip. 

8.

 

Prior to connecting jumpers, replacing circuit components, or touching CMOS pins (if this becomes 
necessary in the replacement of an integrated circuit device), be sure to discharge any static build-up 
as described in procedure 1.  Since voltage differences can exist across the human body, it is 
recommended that only one hand be used if it is necessary to touch pins on the CMOS device and 
associated board wiring. 

9.

 

When replacing a CMOS integrated circuit device, leave the device in its conductive rail container or 
conductive foam until it is to be inserted into the printed circuit module. 

10.

 

All low impedance test equipment (such as pulse generators, etc.) should be connected to CMOS 
device inputs after power is applied to the CMOS circuitry.  Similarly, such low impedance 
equipment should be disconnected before power is turned off. 

11.

 

Replacement modules shipped separately from the factory will be packaged in a conductive material.  
Any modules being transported from one area to another should be wrapped in a similar material 
(aluminum foil may be used).  

Never use non-conductive material

 for packaging these modules. 

Summary of Contents for 4512-001

Page 1: ...ons 1 Description 2 Connectors 3 Power Connector 3 Speaker Connector 4 Microphone Connector 4 Antenna Connector 4 Channel Selector Switch 4 Radio Transceiver Module 5 Interface PCBA 5 Pot R7 5 Wide Ra...

Page 2: ...Battery Connections 13 Microphone Connection 13 Speaker Connection 13 Programming 14 Power Supply Adjustment 14 Speaker Output Adjustment 14 Operation 15 Initiating Calls 15 Receiving Calls 15 Contro...

Page 3: ...arty General Information Scope of Manual This manual provides descriptive data and service information for the following GAI Tronics 6 Channel Radios Model 4512 001 270 V dc Frequencies programmed by...

Page 4: ...4 14 H 3 00 D inches The housing is also a mounting bracket and includes an integral handle The mounting bolts double as support feet when the unit is placed horizontally on a flat surface such as on...

Page 5: ...he location of the connectors and channel selector switch PowerConnector Refer to Figure 3 for the locations of the connectors The pinout for the power connector is as follows Table 1 Model 4512 001 C...

Page 6: ...ur to the speaker and or radio Jumper P6 must be in position 2 3 to activate the carrier detect output Refer to Table 6 on page 5 and Figure 7 on page 12 MicrophoneConnector The microphone pinout is a...

Page 7: ...equencies Do not attempt to program the radio for these frequencies Table 5 UHF 450 470 MHz Receive MHz Transmit MHz 460 80000 460 78750 461 23750 460 79375 461 24375 460 80625 461 25625 460 81250 461...

Page 8: ...nge of input voltages and in addition to the internal protection it is further protected from transients on the external power source by the optional Surge Filter PCBA The power supply provides regula...

Page 9: ...Channel Radios are designed to operate with a rechargeable battery When installed the standby emergency battery supplies power for up to 15 minutes of normal run time with RF set to low power setting...

Page 10: ...computing devices must contain warnings about possible interference with local residential radio and TV reception This warning reads as follows NOTE This equipment has been tested and found to comply...

Page 11: ...ircuit module 4 When servicing a circuit module avoid carpeted areas dry environments and certain types of clothing silk nylon etc because they contribute to static build up Similarly disconnect the t...

Page 12: ...al sheathed or metal clad or are permanently separated from the conductors of the other circuitry by a continuous and firmly fixed nonconductor such as porcelain tubes or flexible tubing in addition t...

Page 13: ...ng the 25 foot coax antenna cable Refer to Figure 6 and Figure 7 for the Models 4512 001 and 4514 001 respectively Select an area for antenna mounting that gives the antenna an unobstructed view of th...

Page 14: ...004 387G Model 4512 001 4512 001FR 4514 001 and 4514 001FR 6 Channel Radios Page 12 of 19 f standard ioms current release 42004 instr manuals 42004 387g doc 02 15 Figure 7 Model 4514 001 Connection Di...

Page 15: ...follows Refer to Figure 4 on page 7 1 Loosen the mounting screw on the right of the 63069 013 Battery Bracket and lift it out of the keyhole slot Slide the battery into place Replace the bracket and...

Page 16: ...tery The charging current can be adjusted using Pot 2 on the Power Supply PCBA Refer to Figure 4 on page 7 for location of Pot 2 If field adjustment becomes necessary the procedure is as follows 1 Dis...

Page 17: ...allow time for the radio channel to be established 2 Speak directly into the microphone held approximately 1 2 inch from the mouth The microphone button must be held down while talking to the radio us...

Page 18: ...ive or malfunctioning equipment should be returned to the factory for repair Please call 1 800 492 1212 or 610 777 1374 to obtain a Return Authorization number published repair prices and shipping ins...

Page 19: ...re 1 0A Slo Blo 5 20mm 250V UL CSA Interface PCBA fuse F2 is 0 1A Slo Blo 5 20mm 250V UL CSA Battery Replacement The optional standby emergency battery is designed to have a shelf life of approximatel...

Page 20: ...r 8 watts maximum into 8 ohms UHF Radio Transceiver General FCC ID AIERT17 445 Frequency range 450 470 MHz Frequency stability 1 5 ppm Tone code signaling CTCSS Quiet Call and DCS Transmitter RF power...

Page 21: ...lead acid 40201 004 Field Replacement Items Description Part No Fuse F1 Power Supply PCBA 1 25A Slo Blo 2AG 250V axial leaded UL CSA 4612 23015 25 Fuse F2 Power Supply PCBA 1 6A Slo Blo 5 20mm 250V U...

Page 22: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: