background image

Pub.  42004-703L2A 

Model 707-001-EX-F07045 SmartSeries Hazardous Area Speaker Amplifier Enclosure  Page:  

10 of 11

 

\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-703l2a.doc 

11/07 

Troubleshooting 

The following table lists some hints to aid technicians in troubleshooting. 

Problem Solution 

Feedback occurs 
only during 
page. 

1.

 

If a speaker is close to the station, try using the muting feature in the amplifier 
enclosure at the terminal blocks.  Connect the violet wire at TB1-8 to TB1-7.  
Refer to the wiring diagram. 

2.

 

Ensure that speakers attached to other stations located nearby are not pointed in 
your direction.  If changing the orientation of the other speakers has no effect, 
mutual muting may be required.  Mutual muting silences all the speakers within 
proximity to the affected stations during a page from any one of the mutually 
muted stations. 

Connect the orange wire (spare) to the TB1-7 of all the stations to be mutually 
muted.  Note: If too many stations are selected, paging coverage can be 
adversely affected. 

3.

 

Check line terminations at the line balance assembly.  Line balance assembly 
connections are critical. 

Crosstalk 
occurs. 

One or more system cable pairs may be improperly terminated.  Visually inspect the 
system cable connections for accidental crossing of the cable pairs or grounds. 

 

Summary of Contents for 707-001-EX

Page 1: ...lifier Enclosure is a component of the 700 Series Page Party system It is constructed of cast aluminum and is extremely weatherproof and corrosion resistant This enclosure is equipped with terminal st...

Page 2: ...Install and tighten all cover bolts to 30 ft lbs Make certain no cover bolts are omitted Use only those bolts supplied with the enclosure When installing an add on station consult the appropriate sys...

Page 3: ...s only applicable approval labeling on the exterior The enclosure itself has 12 cover mounting bolts located around the perimeter and a set of aluminum hinges located on the left side See Figure 2 Out...

Page 4: ...plifier The amplifier bridging plate is hinged on one side and attached on the opposite side with two 10 32 screws For system cable installation the screws to this plate must be removed and the bridgi...

Page 5: ...pable of being rotated 90 This allows for top and bottom mounting feet or side to side mounting feet The enclosure ships with the mounting feet in the top to bottom configuration for ease of installat...

Page 6: ...age 6 of 11 s_eng gtcproddocs standard ioms current release 42004 instr manuals 42004 703l2a doc 11 07 Cable Entries Refer to Figure 5 for the EX cable gland entries Ensure any unused openings are sea...

Page 7: ...nd completely to the terminal block An improper termination may result in diminished station performance See Figure 6 CAUTION For safe operation connect terminal 3 of TB1 to system ground Mutual Mutin...

Page 8: ...Amplifier Enclosure Page 8 of 11 s_eng gtcproddocs standard ioms current release 42004 instr manuals 42004 703l2a doc 11 07 Figure 6 Wiring Diagram Operation Refer to GAI Tronics Pub 42004 699L2 for M...

Page 9: ...ier into the connector in the enclosure Check and if necessary adjust the amplifier to maximize performance 4 Reinstall the amplifier in the enclosure Ensure that all gaskets and hardware are in place...

Page 10: ...attached to other stations located nearby are not pointed in your direction If changing the orientation of the other speakers has no effect mutual muting may be required Mutual muting silences all the...

Page 11: ...blocks Dimensions 15 25 H 15 25 W 9 375 D inches 387 4 387 4 238 1 mm Temperature range operating and storage 4 F to 140 F 20 C to 60 C Shipping weight 75 lbs 34 02 kg Enclosure IP66 Type 4X Approvals...

Page 12: ...of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services e...

Reviews: