15
Auteldac 5
1. The external circuit contains no combined lumped
inductance L
i
and capacitance C
i
greater than 1% of the
above values, or
2. The inductance and capacitance are distributed as in a
cable, or
3. The external circuit contains either only lumped inductance
or lumped capacitance in combination with a cable
In all other situations e.g. the external circuit contains combined
lumped inductance and lumped capacitance, up to 50% of each of
the L and C values is allowed.
The headset must only be used in accordance with the
manufacturer’s instructions supplied with it.
3.4.7
Optional Headset Extension lead
A separate headset extension lead is available as an optional extra,
allowing the operator to extend the headset cord by up to a further 4
metres. Note: Refer to section 1 for hazard warnings regarding long
corded Headsets & handsets.
3.4.8
Alternative cabling schemes
Depending on the options used, different cabling permutations are
possible; some examples are shown below.
Upon installation care should be taken to ensure that incoming
cables are cleanly routed with a view to maintaining segregation
from the telephone's internal wiring (i.e. handset, hookswitch, ringer
and headset if fitted). Segregation must also be maintained between
telephone line and cables to the contacts.
For clarity, the illustrations below are shown with the terminal cover
removed.
The terminal cover must be secured in place before re-
assembling the telephone prior to use.
The terminal cover
provides the required isolation between the cabling in the rear
section and the circuitry in the front section and is critical to the
product's certification.