27
Auteldac 5
•
Incorrect installation of glands (Section 3.2)
•
Incorrect wiring or cable connections (Section 3.4)
•
Improper reassembly following connection
•
Additional holes drilled in casing
5.3 Fault Finding & Field Repairs
The Auteldac 5 contains no user serviceable parts and in the event
of damage or failure must be replaced with a tested telephone of
the correct type.
Refer to section 5.2 for a list of possible fault conditions.
6
TECHNICAL SPECIFICATIONS
6.1 Hazardous Area Certification
It is the responsibility of the installer or user to determine whether or not
Auteldac 5 is suitable for use in a given location or particular
circumstances.
6.1.1
Dust Certification
Certain models (only those fitted with curly cord handsets and with no
headset connector) are certified for use in the presence of combustible
dust. These models have a YELLOW certification label, whereas gas-
only models have a BLUE certification label. Certification details are
listed below
.
6.1.2
IEC Ex Certification
Certificate number: IECEx BAS 14.0165
Certification details:
Gas certified variants (BLUE certification label):
Ex e ib mb IIC T4 Gb (-20
°
C
≤
Ta
≤
+60
°
C)
Ex e ib mb IIC T5 Gb (-20
°
C
≤
Ta
≤
+50
°
C)
Gas & Dust certified variants (YELLOW certification label):
Ex e ib mb IIC T4 Gb (-20
°
C
≤
Ta
≤
+60
°
C)
Ex e ib mb IIC T5 Gb (-20
°
C
≤
Ta
≤
+50
°
C)
Summary of Contents for Auteldac 5