Testing and Troubleshooting
Generating Audio Test Signals
The Model LE200-RM is capable of generating several testing waveforms onto the audio lines of the
page/party system to aid in system testing and troubleshooting. Rotary switch SW1 on the Main PCBA
determines which Page/Party
®
audio line will receive the test waveform. DIP switch SW2 determines
which testing waveform is generated. Closing DIP switch SW2-8 enables the test waveform. Switches
SW2-5 through SW2-7 select a test waveform. Note that the frequency selections are different on the
selected audio party line. Refer to tables below for valid switch settings.
Table 49.
SW1
Selected
Page/Party
®
Line
Selected Tone
SW2-5 SW2-6 SW2-7 SW2-8
1
Party line #1
7 kHz (sine wave)
Open
Open
Open
Closed
6
Page line
4 kHz (sine wave)
Closed
Open
Open
Closed
2 kHz (sine wave)
Open
Closed
Open
Closed
1 kHz (sine wave)
Closed
Closed
Open
Closed
500 Hz (sine wave)
Open
Open
Closed
Closed
125 Hz (sine wave)
Closed
Open
Closed
Closed
1 kHz (saw tooth wave)
Open Closed Closed Closed
31 Hz pulses
Closed Closed Closed Closed
SW1
Selected
Page/Party
®
Line
Selected Tone
SW2-5 SW2-6 SW2-7 SW2-8
2
Party line #2
3.5 kHz (sine wave)
Open
Open
Open
Closed
3
Party line #3
2.0 kHz (sine wave)
Closed
Open
Open
Closed
4
Party line #4
1.0 kHz (sine wave)
Open
Closed
Open
Closed
5
Party line #5
500 Hz (sine wave) Closed
Closed
Open
Closed
250 Hz (sine wave)
Open
Open
Closed
Closed
125 Hz (sine wave)
Closed
Open
Closed
Closed
1 kHz (saw tooth wave)
Open Closed Closed Closed
31 Hz Pulses
Closed Closed Closed Closed
N
OTE
:
Remember to restore SW1 to “0” and SW2 to its initial setting when no longer generating test
signals.