Page
8 of 14
GAI-Tronics 6-Channel Radio
Pub.: 42004-325A
f:\standard ioms - current release\42004 instr. manuals\42004-325a.doc
10/00
Cable Installation Safety Considerations
Interconnecting, communications, and Class 2 dc power cables should be separated from electrical light
or other Class I circuits by at least 2 inches. The exception is where Class I wiring or power circuits are
run in a raceway, or are metal-sheathed or metal-clad, or are permanently separated from the conductors
of the other circuitry by a continuous and firmly fixed nonconductor such as porcelain tubes or flexible
tubing in addition to the insulation on the wire. Communications cables and in-building wiring should be
listed and marked for the purpose according to NEC Article 800.
Surge Protection
The Model TP4514SYN-6 6-Channel Radio (120 V ac) incorporates standard agency-approved surge
protection. The power line fuse on the power supply module must be replaced with the same type fuse to
maintain agency approval and safety protection.
Additional surge protection is available on the TP4512SYN-6 module with additional safety fusing.
These fuses must also be replaced with the same type to maintain agency approval and safety protection.
See the Field Replacement Items section.
Figure 6. TP4512SYN-6 Connection Diagram