Malvern manual  version 1.0                                                                                                                                                    S.D  25.4.2014 

 

Responsibility of the installer.  

It is the responsibility of the installer to inspect the product prior to installation to ensure the unit is free of defect or     
damage. In the event of a problem the unit must not be installed. 

This product complies with internationally recognised safety standards. However  you are responsible for any local 
codes that may apply. 

This product is designed to be installed by a licensed tradesperson. Licensed plumbers and electricians should be  
employed to ensure a proper installation.  Installers assume all liability for the correct installation procedures.  

 

Only accessories authorized by the manufacturer should be used with this product. 

 

Risk of electric shock.  

Connect only to a separate circuit protected by a  30mA RCCD.  

The unit must be connected to a RCCD. This should be tested on a routine basis. To test the RCCD push the test 
button, the RCCD should interrupt power. Push the reset button, power should be restored.  

If the RCCD fails to operate in this manner there is a ground current flowing indicating the possibility of electric 
shock. Do not use this unit.  The unit should be corrected by a qualified representative before any further installation 
is undertaken. 

 

Risk of electric shock

. Spa motors where fitted should be connected to a separate 30mA RCCD protected outlet.  

Note: The unit must not be fitted in the bathroom area unless protected by an RCCD.  

 

Classification & technical data.  

Fixed class 1 installation 

Type B applied part 

Not suitable for use in the presence of flammable anaesthetic mixture with air or oxygen or nitrous oxide.  

Rated supply 230v, 240W 60Hz refer to label. 

Maximum patient weight: 22 stones . 150kg  (140 Kg transfer systems) 

Maximum weight of bathtub, patient and water 420Kg  

Maximum weight of complete transfer system . 33kg  

Suitable for intermittent use only  - 2 minutes on  - 18 minutes off.  

The power pack is low voltage and runs at 24v DC . Immediately after installation and prior to use it is vital that the 
bath is connected to a mains supply for at least 24 hours before initial use to ensure the batteries are fully charged. 

Failure to comply with this requirement could result in the user not being able in the event of a mains power failure. 

 

 

 

 

Summary of Contents for MALVERN

Page 1: ...1 Malvern manual version 1 0 S D 25 4 2014...

Page 2: ...014 1 Cover 2 Contents 3 Pre installation 1 4 Pre installation 2 5 Pre installation water pressure 6 Installation 1 7 Installation 2 8 User Guide 1 9 User Guide 2 Transfer system 10 User Guide 3 11 Ma...

Page 3: ...tray and fill this using a concrete mix Alternatively timber joists can be anchor bolted to the concrete sub floor to provide the needed support The finish should come level with the surface floor b I...

Page 4: ...THIS Minimum distance between the walls and baths bath sides is 150mm When deciding on the position of the bath there are a number of points that should be considered 1 Hoist and wheel chair access 2...

Page 5: ...r pressure of 1 5 bars with a maximum pressure loss no greater than 10 1 between hot and cold feeds It is important to note that a pressure difference between hot and cold pipes will have a great effe...

Page 6: ...in this manner there is a ground current flowing indicating the possibility of electric shock Do not use this unit The unit should be corrected by a qualified representative before any further install...

Page 7: ...tion position H Manoeuvre the bath into its installation position I Remove the transportation wheels and cross tie bars J Set the base distances to 1473mm K Mark the position of the floor fixing holes...

Page 8: ...to be used at all times when the unit is operated with a seated user The bath lift is independent to the seat To raise the bath the seat must be inside the bath in the raised position NOTE the bath wi...

Page 9: ...eved by pressing and holding down the out of water button on the handset The arm will stop automatically when it is fully lowered Note that the bath must be fully lowered before the arm will traverse...

Page 10: ...empty any water still inside the hose and then place the handset back into it s mount User safety notes To reduce the risk of injury do not permit children or persons with infirmities to use this pro...

Page 11: ...ode 1 Lift actuator fault One long flash followed by 1 short flash Code 2 Traverse actuator fault One long flash followed by 2 short flashes Code 3 Leg Lift actuator fault One long flash followed by 3...