Please note
: As a professional user you are responsible for the quality of the final
formulation. Please always check the quality of the final product prior delivering to the
client.
After each completed mixing process the UNGUATOR® Q generates an identification
number which contains all mixing parameters. You have the opportunity to save, record or
reject the number. Saving the formulation enables you to individually name it. Rejecting
the identification number would not allow the data being retrieved again and the
information is lost.
If the mixing process has been interrupted the UNGUATOR® Q does not generate any
identification number.
You may continue mixing on your own responsibility or starting the mixing process over.
If you wish to modify or edit any individual formulation, select the defined formulation
with “+” or “-” and press down the “ok” key for min. 3 seconds. You may then adjust
and modify the formulation. To save it, please press down the “ok” key again for min. 3
seconds.
To delete any individual formulation, select the defined formulation with “+” or “-” and
press down the “ESC” key for min. 3 seconds. You may now delete the defined formulation.
To verify, a security inquiry will appear, which you may accept or reject.
6.4.4 Standard
The “Standard” program allows you to choose from a list of standard mixing programs
based on the galenic administration of the particular formulation to be manufactured.
With “+” or “-” you may browse the list of programs and enter with “ok”. At the next step
you are prompted to define the jar sizes with “+” or “-”, which you enter with “ok”.
Pregrinding program
The pregrinding program serves to moisten solids in the preparation of suspensions with
an active substance content <2%, allowing a homogeneous distribution of the active
ingredient in an ointment base.
As an example, incorporation of corticoids, antibiotics, fungicides or hormones in an
ointment base. In order to ensure a homogeneous processing, we recommend using the
UNGUATOR® standard mixing blade.
First, load approximately 30% of the defined ointment base in the UNGUATOR® jar
embedding the micronized agents afterwards. The agent has to be integrated in the
ointment base in order to avoid powder residue sticking on the blade.
22