18
PARAMETER UNIT
The followings will describe in depth about the parameter unit:
1.
HOW TO CHANGE PARAMETERS
Press
. Enter a parameter number
Press . Enter a new value. Press . Wait for the Completed signal from the LCD display.
2.
HOW TO READ (COPY) FROM A DRIVE
Press
. Press .
Press . Wait for the Completed signal from the LCD display.
3.
HOW TO WRITE (DOWNLOAD) TO A DRIVE
Press
. Press .
Press . Wait for the Completed signal from the LCD display.
4.
HOW TO VERIFY ENCODER DIRECTION
Press
. Run the door in Manual mode using the toggle switches.
If the door Closes and the counter Decreases, or the door Opens and the counter Increases, then the
encoder Direction is Correct. Otherwise, change parameter 42.
5. HOW TO LEARN THE DOOR WIDTH
Flip the RUN|SETUP switch to SETUP. Set Par. 63 = 1.
Flip the RUN|SETUP switch to RUN. Use Manual mode to run
the door from DOL to DCL, or vice versa.
Follow the prompts on the LCD display. LEARN DOOR WIDTH
LED will flash and turn off when the learning process is completed.
Par. 63 will sets itself back to Zero.
See Parameter Adjustments section, in the Manual, for more details.
The Parameter Unit is a tool to assist users in the following tasks:
ł Learning the door widths of the regular door and narrower door.
ł Changing accelerations, decelerations, speeds, torques, and all
pertinent parameters of peripheral devices. See the defaults
parameters table for more details.
ł Downloading (copying, reading), uploading (writing) to and
from the drive.
ł Storing all default sets of parameters and a reference working
set of parameters.
ł Monitoring currents, voltages, inputs, outputs, faults, encoder
directions, closing time.
ł Resetting the drive.
SET
VOLT
PULSE
WRITE
READ
SET
READ
SET
WRITE
:
Parameter Unit not included, if required part # 2500-3051
18
Summary of Contents for MOVFE 2500
Page 1: ...2500 3069 1 888 425 2262 2500 3069 ELECTRICAL...
Page 2: ...Rev 1 10 20 I...
Page 24: ...19 6 DEFAULT PARAMETERS 19...
Page 26: ...21 FAULTS AN EXAMPLE OF FAULTS DISPLAY COUNTERS 21...
Page 27: ...22 USER LIST 22...
Page 28: ...23 23...
Page 29: ...24 24...
Page 30: ...25 25...
Page 31: ...26 MAXIMUM CLOSE SPEED AND FORCE 26...
Page 32: ...27 ECI DEFAULT PARAMETER SETS 27...
Page 34: ...29 SPEED PROFILES OF THE VFE2500 FOR NORMAL DOOR 29...
Page 35: ...30 SPEED PROFILES OF THE MOVFE2500 FOR HEAVY DOOR 30...
Page 36: ...31 SPEED PROFILES OF THE MOVFE2500 FOR NARROW DOOR 31...
Page 91: ...Rev 10 20 85...
Page 92: ......