OverloadTime
GROUP7:COMMUNICATIONPARAMETERS
Par.
No
Description
Range
Unit
DefaultSetting
Display
RelatedPar.
240
RS485
NodeNumber
1Ͳ254
1
CommNodeAddr
241
RS485
Baudrate
0Ͳ3
0:Baudrate4800bps
1:Baudrate9600bps
2:Baudrate19200bps(DF)
3:Baudrate38400bps
CommDataRate
242
RS485
Modbus
Protocol
0–5
0:7,N,2(Modbus,ASCII)
1:7,E,1(Modbus,ASCII)
2:7,O,1(Modbus,ASCII)
3:8,N,1(Modbus,RTU)(DF)
4:8,E,1(Modbus,RTU)
5:8,O,1(Modbus,RTU)
CommFormat
243
RS485
ConnectionLoss
0Ͳ3
0:Warnandkeepoperating
1:Warnandramptostop
2:Warnandcoasttostop
3:Nowarningandkeep
operating.(Default)
CommLossAction
244
RS485
ConnectionLoss
Time
0.0–
60.0
sec
0.0sec
CommLossTM
246
CAN
NodeAddress
0Ͳ255
7
CANNodeAddr
247
CAN
Baudrate
0Ͳ
65535
kbps 115.2Kbps
CANDataRate
DISPLAYPARAMETERS
Par.
No
Function
Display
Unit
D0
Drive Status 1
Bit 0 Reserved
Bit 1 0
᧶
STOP
᧨
1
᧶
RUN
Bit 2 Reserved
Bit 3 0
᧶
CLOSE
᧨
1
᧶
OPEN
Bit4~5 Reserved
Bit 6 1
᧶
OVT
Bit 7 1
᧶
FLT
Bit 8~10 Reserved
Bit 11 1
᧶
Factory Set
Bit 12 Reserved
Bit 13~15 100
᧶
NUD
000
᧶
HLD
Drive Status 1
hex
D1
Output Frequency
Output Freq
Hz
48
Summary of Contents for MOVFE 2500
Page 1: ...2500 3069 1 888 425 2262 2500 3069 ELECTRICAL...
Page 2: ...Rev 1 10 20 I...
Page 24: ...19 6 DEFAULT PARAMETERS 19...
Page 26: ...21 FAULTS AN EXAMPLE OF FAULTS DISPLAY COUNTERS 21...
Page 27: ...22 USER LIST 22...
Page 28: ...23 23...
Page 29: ...24 24...
Page 30: ...25 25...
Page 31: ...26 MAXIMUM CLOSE SPEED AND FORCE 26...
Page 32: ...27 ECI DEFAULT PARAMETER SETS 27...
Page 34: ...29 SPEED PROFILES OF THE VFE2500 FOR NORMAL DOOR 29...
Page 35: ...30 SPEED PROFILES OF THE MOVFE2500 FOR HEAVY DOOR 30...
Page 36: ...31 SPEED PROFILES OF THE MOVFE2500 FOR NARROW DOOR 31...
Page 91: ...Rev 10 20 85...
Page 92: ......