DISPLAYPARAMETERS(CONTINUED)
Par.
No
Function
Display
Unit
D2
Commanded Frequency
Commanded Freq
Hz
D3
Output Current
Output Current
A
D4
Output Voltage
Output Voltage
V
D5
DC Bus Voltage
DC Bus Voltage
V
D6
Door Close Time
Door Close Time
sec
D7
Switch Input Status
Bit0 0: SETUP 1:RUN
Bit1 0:MAN 1:AUTO
Bit2 OPEN
Bit3 CLOSE
Bit4 NUDG
Bit5 NARROW
Bit6 RESET
Bit7 HEAVY
SW IN 87654321
D8
Digital Input Status
Bit0 CLOSE
Bit1 OPEN
Bit2 NUDG
Bit3 NARROW
Bit4 HEAVY
Bit5 IR
Bit6 SPARE-1
Bit7 SPARE-2
MI IN 87654321
D9
Sensor Input Status
Bit0 HALL-DOL
Bit1 HALL-AUX
Bit2 HALL-DPM
Bit3 HALL-DCL
Bit4 HALL-SPARE1
Bit5 HALL-SPARE2
Bit6 HALL-SPARE3
Bit7 OPTIC-DOL
Bit8 OPTIC-AUX
Bit9 OPTIC-DPM
Bit10 OPTIC-DCL
SenseCPAO321CPAO
D10
Counter Status 1 (unit: 1)
Counter Status 1
D11
Counter Status 2 (unit: 10000)
Counter Status 2
D12
Relay Output Status
Bit0 EDGE Timeout
Bit1 AUX
Bit2 DPM
Bit3 REOPEN
Bit4 DOL
Bit5 DCL
Bit6 SPARE-1
Bit7 SPARE-2
RelayOUT87654321
49
Summary of Contents for MOVFE 2500
Page 1: ...2500 3069 1 888 425 2262 2500 3069 ELECTRICAL...
Page 2: ...Rev 1 10 20 I...
Page 24: ...19 6 DEFAULT PARAMETERS 19...
Page 26: ...21 FAULTS AN EXAMPLE OF FAULTS DISPLAY COUNTERS 21...
Page 27: ...22 USER LIST 22...
Page 28: ...23 23...
Page 29: ...24 24...
Page 30: ...25 25...
Page 31: ...26 MAXIMUM CLOSE SPEED AND FORCE 26...
Page 32: ...27 ECI DEFAULT PARAMETER SETS 27...
Page 34: ...29 SPEED PROFILES OF THE VFE2500 FOR NORMAL DOOR 29...
Page 35: ...30 SPEED PROFILES OF THE MOVFE2500 FOR HEAVY DOOR 30...
Page 36: ...31 SPEED PROFILES OF THE MOVFE2500 FOR NARROW DOOR 31...
Page 91: ...Rev 10 20 85...
Page 92: ......