65
NOTES:
MINIMUMCLOSINGCODETIME(ECIREFERENTIALVALUE)
MinimumclosingcodetimesareobtainablefromtheLCDkeypadbyenteringthefollowings:
DOORTYPESELECTION
(HARMONIC,STRAIGHTLINEAR,ORGEAREDLINEAR)
ENTERBYECIDEFAULTS.
PAR.52(READONLY)
0:HARMONIC,S/O
1:HARMONIC,C/P
2:LINEARͲSTRAIGHT,S/O
3:LINEARͲSTRAIGHT,C/P
4:LINEARͲGEARED,S/O
5:LINEARͲGEARED,C/P
ENTERDOORWIDTH(INCHES)
Î
PAR.49
ENTERDOOR(S)WEIGHT(LBS)
Î
PAR.50
ENTERSINGLEͲSPEEDORTWOͲSPEED
SELECTION
0:SINGLESPEED
1:TWOSPEED
Î
PAR.51
ECI
MINIMUM
CLOSING
CODETIME
TABLES
REFERENTIALCLOSINGCODETIMES.
9.DISPLAYGROUP
D21:MINIMUMCLOSINGCODETIME
D22:MINIMUMCLOSINGCODETIME
FORNUDGING