TIG 3200 AC/DC
41
5.2.5. TIG AC PROCESS – PULSED ARC.
This type of arc has the purpose of obtaining a greater control over the welding contribution. The result is a sequence of
2 intensities that overlap as a cord. The pulsed regulation frequency (FHz) will be performed from Table 4 (See AC Cycle
Parameters).
For example: a low frequency marks the cord waters. On the contrary, a high frequency marks them less.
We can regulate the alternating current frequency (FAC Control), besides adjusting the wave balance (Control Balance)
and adapting the penetration of the cord (Penetration Control).
KEY
ACTION
DESCRIPTION
P1
Back to Main Menu
P2
Access to Program File
P3
Access to Operation mode
P4
Access to Parameters Cycle
Access specific process cycle and selected mode.
P5
Select secondary correction
Temporarily place secondary correction in main position.
E1
Modify Main Correction
Set frecuency AC.
Set balance AC.
Set penetration AC.
E2
Modify Master Value
Set the welding intensity.