GALA MIG (V. COMPACTA). Manuel d'Instructions
15
Control pannels of GALA MIG (V. Compacta) equipment.
B - Wire speed control potentiometer.
C- SPOT TIME: Welding time control potentiometer.
D - Welding voltage selector switch.
E- Fuse-holder. (1A/250V fuse)
F- Thermal overload indicator.
G- Luminous ON/OFF switch.
R/S- Digital voltmeter-Ammeter. Measures the voltage and intensity
of the welding circuit. (*)
GALA MIG 1810
WARNING!: This equipment has thermal protection against
overheating. In the event that you exceed the duty cycle of the
equipment, the light H will come on and the equipment will not be
operative. Wait until the equipment cools down appropriately. (Do not
disconnect the machine).
GALA MIG 2300 ALU 4R
B - Wire speed control potentiometer.
C- SPOT TIME: Welding time control potentiometer.
D - Welding voltage selector switch.
E- Fuse-holder. (1A/250V fuse)
G- Luminous ON/OFF switch.
H- SOFT START: Initial acceleration ramp control of driving motor.
The abruptness of the start of the arc can be decreased with this,
creating a progression of the motor speed.
I- BURN-BACK: Final wire length control. It adjusts the final wire
length at the outlet from the torch.
R/S- Digital voltmeter-Ammeter. Measures the voltage and intensity
of the welding circuit. (*)
GALA MIG 2000/ 2600
B - Wire speed control potentiometer.
C- SPOT TIME: Welding time control potentiometer.
D - Welding voltage selector switch.
E- Fuse-holder. (1A/250V fuse)
G- Luminous ON/OFF switch.
R/S- Digital voltmeter-Ammeter. Measures the voltage and intensity
of the welding circuit. (*)
GALA MIG 4000
B - Wire speed control potentiometer.
C- SPOT TIME: Welding time control potentiometer.
D- Welding voltage fine adjustment changeover switch.
E- Fuse-holder. (1A/250V fuse)
G- Scale switch. ON/OFF switch.
H- SOFT START: Initial acceleration ramp
control of driving
motor. This permits reducing abruptness of the arc start,
creating a progression in the motor start-up speed.
I- BURN-BACK: Final wire length control. It
adjusts the final
wire length at the outlet
from the torch.
J- ON indication lamp.
R/S- Digital voltmeter-Ammeter. Measures the voltage and intensity
of the welding circuit. (*)
(*)Standard Models: Optional KIT Ref 43981075. Included in GALAMIG V-I models
A
Torch connection.
E
T 1A/250V
Protection fuse.
B
Wire speed control.
F
Thermal overload warning light. (GALA MIG
1810)
C
SPOT TIME. Spot time.
H
SOFT-START: Soft control on initial arc
striking.
M
Welding earth connection.
I
BURN-BACK: Final wire length control.
C