background image

 

GALA MIG 257.  

14 

 

 

4. MAINTENANCE OPERATIONS. RECOMMENDATIONS. 

Before carrying out any operation on the machine or gun, we must place switch I of the equipment in "O" 

position of machine disconnected. Specialized personnel must handle the machine to carry out maintenance 
and repair operations

.

 

)

 

BLOW THE INSIDE OF THE MACHINE WITH COMPRESSED AIR FROM TIME TO TIME. 

)

 

PLACE THE EQUIPMENT SOMEWHERE WHERE CLEAN AIR IS RENEWED. 

)

 

KEEP THE MACHINE PANELS CLOSED. 

)

 

DO NOT DISCONNECT THE MACHINE IF IT IS HOT. 

)

 

KEEP THE WELDING GUN IN GOOD CONDITIONS FOR USE. 

 

5. ANOMALIES. PROBABLE CAUSES. POSSIBLE SOLUTIONS.

 

SYMPTOM. ANOMALY. 

 

PROBABLE CAUSE. 

 

POSSIBLE SOLUTION.

 

1. Make sure there is voltage at the entry to the 
machine, if not the tapping must be changed. It is 
advisable to see if any magnetothermal has "blown".
2. Check that fuse T of the power source is not open.

 
GENERAL PROBLEM 

NOTHING WORKS

 

The machine has no voltage in one or all its 
vital elements. 
 

 

3.  The machine panels must be removed testing the 
logical points of the electrical diagram.

 

LIMITER TRIPS 
 

Magnetothermal switch has low gauge for the 
case. There may be a short circuit, which is 
what causes the limiter to trip.

 

   Change the magnetothermal for another larger 
gauge one. It is important for the magnetothermal 
switch to have a characteristic slow type curve. 

 

Problem in the internal connection.  

 

Check that the internal connections are corrects. 

 

The thermal protection has “blown”.  Pilot F 
illuminated.  

 

Wait until the machine cools down correctly.  Do not 
disconnect the machine. 

 

 Faulty electronic card. 

 

Replace the electronic card.

 

ALTHOUGH THE MACHINE IS 

CONNECTED AND WITH THE 
SWITCH ON, THERE IS NO 
REACTION WHEN PRESSED

 

 Failure of the pistol switch which does not 
make perfect contact.

 

Change the gun microswitch.

 

WHEN THE GUN IS PRESSED, 
ALTHOUGH WIRE COMES OUT, 
THE CONTACTOR DOES NOT 
WORK OR/AND THERE IS NO 
SHIELDING GAS. 

 

Voltage does not reach the Contactor or/and 
solenoid valve.

 

It must be established whether the fault comes from 
the electronic board or if it is an electrical connection 
fault. 
Check that the contactor coils or/and solenoid valve 
are not open.

 

WHEN THE SHIELDING GAS IS 
RELEASED IT CONTINUES 

FLOWING. 
 

There is impurity in the inside chamber of the 
solenoid valve which prevents the piston from 

closing completely.

 

Dismantle and clean the electrovalve.

 

WHEN FINISHING WELDING 
THE WIRE REMAINS STUCK TO 
THE TORCH CONTACT TUBE.

 

The contactor has a very high opening delay.

 

Suitably regulate the post-flux potentiometer of the 
electronic card.  

 

WHEN FINISHING WELDING 
THE FINAL WIRE LENGTH IS 

VERY GREAT.

 

The contactor has a very low opening delay.

 

Suitably regulate the post-flux potentiometer of the 
electronic card.  

 

THE EQUIPMENT DOES NOT 
WELD CORRECT.  
 "IT ADJUSTS BADLY"

 

Low effective welding voltage. Output wave not 
correct.

 

Check that there is not a phase failure in the supply 
power. 
Check that the electrical contact elements of the 
welding circuit are correct: Welding mass, rusty or 
very dirty surfaces, contact nozzle with greater 
diameter than the wire, etc.

 

Test the electrical diagram of the power source: input 

and output voltages to the rectifier.

 

The welding wire has a mechanical resistance 
at the outlet, which prevents it from having a 
regular speed.

 

Examine the welding gun. Blow the inside (cable) 
with compressed air. 

 

THERE ARE MANY PROJECTIONS 
IN THE WELDING PROCESS

 

Unsuitable shielding gas.

 

When welding normal steels we advise the use of a 
gas mixture Ar-CO2.

 

 
 
 
 

 

Summary of Contents for GALA MIG 257

Page 1: ...f 469 00 000 E ESTE EQUIPO DEBE SER UTILIZADO POR PROFESIONALES EN BENEFICIO DE SU TRABAJO LEA ATENTAMENTE ESTE MANUAL GB THIS EQUIPMENT MUST BE USED BY PROFESSIONALS TO HELP YOU IN YOUR WORK CAREFULL...

Page 2: ...ANNEXES Pag 32 D CLARATION DE CONFORMIT MARQUAGE CE PLANS LECTRIQUES PLAN CLAT ET LISTES DE R F RENCES P NDICE CAP TULO 1 DESCRI O GERAL CARACTER STICAS T CNICAS P g 24 CAP TULO 2 TRANSPORTE E INSTAL...

Page 3: ...x 19 41V Numero de escalonamientos U2 10 Sistema de arrastre 2 Ruletas 50 W Di metros de hilo aplicables mm 0 6 0 8 1 0 Velocidad m xima de hilo 24 m min Aplicaci n soldadura por puntos SPOT SI Contro...

Page 4: ...n el equipo Instalaci n el ctrica Interruptor magnetot rmico Curva D GALA MIG 257 3P 16 A 230V 3P 10 A 400V Manguera de alimentaci n RVK 1KV GALA MIG 257 Longitud 230 V 400 V 10 m 1 5 mm2 1 5 mm2 15 2...

Page 5: ...a cadena de seguridad est perfectamente fijada 4 Coloque el manorreductor y conecte el tubo del gas comprobando que ste no tiene p rdidas a lo largo de todo el circuito 5 Coloque sobre la bobina de hi...

Page 6: ...sor de la pieza Puede utilizarse CO2 puro aunque no lo recomendamos ya que si bien proporciona mayor penetraci n de soldadura da un aspecto de la costura soldada peor siendo adem s el n mero de proyec...

Page 7: ...CTADA Y CON EL INTERRUPTOR ILUMINADO AL PULSAR NO EXISTE NING N TIPO DE REACCI N Fallo del interruptor de la pistola que no realiza perfectamente el contacto Cambiar microinterruptor de la pistola AL...

Page 8: ...edores de Cables de potencia control se alizaci n y tel fono Receptores y transmisores de radio y televisi n Ordenadores y otros equipos de control Equipo cr tico de seguridad Personas con estimulador...

Page 9: ...alg n tipo de tratamiento superficial cincado galvanizado etc Ev tese en todo momento la inhalaci n de los humos desprendidos en el proceso Prot jase del humo y polvo met lico que pueda originarse Uti...

Page 10: ...Welding voltage U2min U2max 19 41 V Number of staggerings U2 10 Drive system 2 Rollers 50 W Applicable wire diameters mm 0 6 0 8 1 0 Maximum wire speed 24 m min Spot welding application SPOT YES SOFT...

Page 11: ...the equipment Electrical installation Magnetothermal switch Curve D GALA MIG 257 3P 16 A 230V 3P 10 A 400V Power supply hose RVK 1KV GALA MIG 257 Length 230 V 400 V 10 m 1 5 mm2 1 5 mm2 15 20 m 2 5 m...

Page 12: ...e holder system and above all check that the safety chain is properly placed 4 Install the pressure reducing valve and connect gas hose checking that there are no leakages throughout the whole circuit...

Page 13: ...on the wire diameter and the part thickness Pure CO2 can be used although we do not recommend this as since it provides greater welding penetration the aspect of the welded seam is worse and also the...

Page 14: ...ITCH ON THERE IS NO REACTION WHEN PRESSED Failure of the pistol switch which does not make perfect contact Change the gun microswitch WHEN THE GUN IS PRESSED ALTHOUGH WIRE COMES OUT THE CONTACTOR DOES...

Page 15: ...of the following in the surrounding area must be kept in mind Wiring for power control signalling and telephones Radio and television receivers and transmitters Computers and other control equipment C...

Page 16: ...als which have some kind of surface coating zinc plated galvanised etc Avoid inhaling the fumes given off in the process at all times Protect yourself from the fumes and metal dust which can be given...

Page 17: ...Nombre d chelonnements U2 10 Moteur d entra nement 2 Galets 50 W Diam tres de fil applicables mm 0 6 0 8 1 0 Vitesse maximum de fil 24 m min Application soudage par points SPOT OUI Application de dema...

Page 18: ...e dans l quipement Installation lectrique Interrupteur magn tothermique Courbe D GALA MIG 257 3P 16 A 230V 3P 10 A 400V C ble d alimentation RVK 1KV GALA MIG 257 Longueur 230 V 400 V 10 m 1 5 mm2 1 5...

Page 19: ...rtout si la cha ne de s curit est bien fix e 4 V rifier le d tendeur et brancher le tuyau du gaz en v rifiant s il n y a pas de fuites tout au long du circuit 5 Poser l adaptateur correspondant sur la...

Page 20: ...e du fil et de l paisseur de la pi ce Du CO2 pur peut tre utilis bien que nous ne le recommandons pas car m me s il fournit une meilleure p n tration de soudage il donne un aspect de point de soudage...

Page 21: ...R ACTION M ME EN PRESSANT Erreur de l interrupteur du galet qui ne fait pas bien contact Changer le microinterrupteur du pistolet EN PRESSANT LE PISTOLET M ME SI LE FIL SORT LE CONTACTEUR N AGIT PAS E...

Page 22: ...tours de C bles de puissance contr le signalisation et t l phone R cepteurs et transmetteurs de radio et t l vision Ordinateurs et autres quipements de contr le quipement critique de s curit Personnes...

Page 23: ...tr s toxique Ceci peut galement arriver avec le mat riel qui a re u un traitement zingage galvanisation etc viter tout moment l inhalation des fum es de soudage Utiliser une protection contre la fum e...

Page 24: ...x 19 41V Numero de escalonamentos U2 10 Sistema de acionamento 2 Roleta 50 W Di metros de fio aplic veis mm 0 6 0 8 1 0 Velocidade m xima de fio 24 m min Aplica o soldadura por pontos spot SI Aplica o...

Page 25: ...tala o el ctrica Interruptor magnetot rmico Curva D GALA MIG 257 3P 16 A 230V 3P 10 A 400V Mangueira de alimenta o RVK 1KV GALA MIG 257 Longitud 230 V 400 V 10 m 1 5 mm2 1 5 mm2 15 20 m 2 5 mm2 2 5 mm...

Page 26: ...ve que a cadeia de seguran a esteja perfeitamente fixada 4 Coloque o manorredutor e ligue o tubo do g s comprovando que n o tem perda ao longo de todo o circuito 5 Coloque sobre a bobina de fio o adap...

Page 27: ...espessura da pe a Pode utilizar se CO2 puro embora n o venha recomendado j que pode proporcionar maior penetra o de soldadura mas d um aspecto da costura soldada pior sendo ademais o n mero de projec...

Page 28: ...O INTERRUPTOR ILUMINADO AO PULSAR N O EXISTENENHUM TIPO DE REAC O Falha do interruptor da pistola que n o realiza perfeitamente o contacto Mudar o microinterruptor da pistola AO PULSAR A PISTOLA EMBOR...

Page 29: ...ncia controlo sinaliza o e telefone Receptores e transmissores de r dio e televis o Computadores e outros equipamentos de controlo Equipamento cr tico de seguran a Pessoas com estimuladores card acos...

Page 30: ...ncorporem algum tipo de tratamento superficial zincado galvanizado etc Evite se em todo momento a inala o dos fumos desprendidos no processo Proteja se do fumo e p met lico que possa originar se Utili...

Page 31: ...s o gastos imprevistos o indirectos resultantes de un uso incorrecto no ser n responsabilidad de GALA GAR GB APPENDICES ELECTRICAL DRAWINGS AND REFERENCE PART LISTS DECLARATION OF CONFORMITY EC MARKIN...

Page 32: ...l usager Les dommages ou les frais impr vus ou indirects r sultant d un usage incorrect d chargeront GALA GAR de toute responsabilit P ANEXOS PLANOS EL CTRICOS E LISTAGEM DE PE AS DECLARA O DE CONFOR...

Page 33: ...CAL CONSTRUCTIONS FABRICATION ET VENTE D APPAREILS DE SOUDAGE AUTOG NE LECTRIQUE ET CONSTRUCTIONS LECTROM CANIQUES FABRICO E VENDA DE APARELHAGENS DE SOLDADURA AUTOG NEA EL CTRICA E CONSTRU ES ELECTRO...

Reviews: