background image

 

 

 

 

Smart 140 MMA battery

 

 

 

 

 

ES 

MANUAL TÉCNICO DE INSTRUCCIONES. 
EQUIPOS INVERTER DE SOLDADURA AL ARCO 

EN 

TECHNICAL INSTRUCTIONS MANUAL.  
ARC WELDING INVERTER EQUIPMENT 

 

 

 

 

 

Ref. 223.00.140BT 

Smart 140 MMA Battery

 

 
 
 

ES 

 

ESTE EQUIPO DEBE SER UTILIZADO POR PROFESIONALES. 

EN BENEFICIO DE SU TRABAJO LEA ATENTAMENTE ESTE MANUAL. 

EN 

 

THIS EQUIPMENT MUST BE USED BY PROFESSIONALS. 

TO HELP YOU IN YOUR WORK CAREFULLY READ THIS MANUAL. 

 

 

 

 

Jaime Ferrán 19 50014 ZARAGOZA (España) 

Tel. - 34/976473410  Fax - 34/976472450

 

 
 
 
 

Ref: M-22300140BT V0

Summary of Contents for Smart 140 MMA

Page 1: ...EQUIPMENT Ref 223 00 140BT Smart 140 MMA Battery ES ESTE EQUIPO DEBE SER UTILIZADO POR PROFESIONALES EN BENEFICIO DE SU TRABAJO LEA ATENTAMENTE ESTE MANUAL EN THIS EQUIPMENT MUST BE USED BY PROFESSIO...

Page 2: ...Smart 140 MMA battery 2 NOTAS...

Page 3: ...g 20 ANEXOS P g 21 CONDICIONES GENERALES DE GARANT A DECLARACI N DE CONFORMIDAD MARCADO CE HOJA DE REPUESTOS PLANOS EL CTRICOS EN CONTENTS CHAPTER 1 GENERAL DESCRIPTION TECHNICAL SPECIFICATIONS P g 1...

Page 4: ...ctura Lampara intensiva de iluminaci n Sistema de ventilaci n inteligente ecoventilador CARACTER STICAS T CNICAS SMART 140 MMA BATTERY Ref 22300140BT Proceso de soldadura Electrodo Revestido MMA Acumu...

Page 5: ...in de reducir la ca da de voltaje se recomienda un cable con mayor rea de secci n si el cable es demasiado largo tendr un gran impacto en el rendimiento del arco o incluso en otras prestaciones del si...

Page 6: ...tensi n de soldadura B Conector del polo positivo de tensi n de soldadura C Potenci metro de control del valor de la corriente de soldadura D Medidor del nivel de bater a E ON OFF Diodo luminoso Indic...

Page 7: ...naval tanques de almacenamiento estructuras recipientes a presi n refiner as de petr leo calderas y cualquier tipo de tuber a de conducci n son alguno de sus sectores de aplicaci n Las caracter stica...

Page 8: ...sta forma reduciremos las perturbaciones electromagn ticas Siempre que circula corriente el ctrica se genera un campo magn tico circular alrededor del conductor este campo magn tico se genera desde la...

Page 9: ...a debe ubicarse en un emplazamiento donde exista renovaci n de aire LA MAQUINA DEBE FUNCIONAR SIEMPRE CON LA ENVOLVENTE PUESTA NO DESCONECTE LA MAQUINA SI ESTA SE ENCUENTRA CALIENTE Si ha acabado el t...

Page 10: ...uminado Equipo sobrecalentado espere a que el equipo se enfr e Posible aver a en circuito de potencia SE QUEMA EL ELECTRODO EN SOLDADURA TIG Intensidad de soldadura excesiva para un determinado electr...

Page 11: ...disolventes dado que estas pueden descomponerse en el proceso de soldadura desprendiendo un humo que puede ser muy t xico Esto mismo puede suceder con aquellos materiales que incorporen alg n tipo de...

Page 12: ...tensive lighting lamp Intelligent ventilation system ecofan Basic technical characteristics TECHNICAL SPECIFICATIONS SMART 140 MMA BATTERY Ref 22300140BT Welding process Electrodo Revestido MMA Batter...

Page 13: ...ON When a long output cable is used in order to reduce the voltage drop the cable with a larger section area is recommended if the cable is too long it will have great impacts on the arcing performanc...

Page 14: ...A Negative pole connector for the welding voltage B Positive pole connector for the welding voltage C Control potentiometer of the welding current value D Battery level meter E ON OFF Luminous diode S...

Page 15: ...res pressure containers oil refineries boilers and any type of piping are some of its application sectors The main characteristics of the process are its simplicity and its low price making it a pract...

Page 16: ...Whenever electric current circulates a circular magnetic field is generated around the conductor This magnetic field is generated from the connection of the negative pole to the positive pole This phe...

Page 17: ...st be kept free It must be located in a place where clean air is renewed C THE MACHINE MUST ALWAYS BE OPERATED WITH THE HOUSING ON D DO NOT DISCONNECT THE MACHINE IF IT IS HOT If you have finished the...

Page 18: ...ction system Amber light E on Equipment overheated wait until the equipment cools down Supply voltage outside rated margin Change supply tap THE ELECTRODE BURNS IN TIG WELDING Excessive welding intens...

Page 19: ...s can also occur with those materials which have some kind of surface coating zinc plated galvanised etc Avoid inhaling the fumes given off in the process at all times Protect yourself from the fumes...

Page 20: ...tilizaci n sostenible de los recursos materiales Para desechar de forma segura su dispositivo utilice los sistemas de recolecci n y devoluci n correspondientes Correct recycling of the product This ma...

Page 21: ...gastos imprevistos o indirectos resultantes de un uso incorrecto no ser n responsabilidad de GALA GAR GENERAL GUARANTEE CONDITIONS GALA GAR guarantees correct operation against all manufacturing defec...

Page 22: ......

Page 23: ...RCA O 1 GALA GAR DECLARES THAT THE PRODUCT AND ACCESSORIES SUPPLIED AND REFERENCED IN THE INSTRUCTION MANUAL COMPLY WITH THE STANDARDS DESCRIBED BELOW APPLICABLE FOR 1 MARKING GALA GAR D CLARE QUE LE...

Page 24: ......

Page 25: ...ESQUEMA EL CTRICO...

Page 26: ...RD 6 22300140BT06 PLACA CONTROL PANEL PANEL CONTROL BOARD 7 22300140BT07 PANEL FRONTAL FRONT PANEL 8 22300140BT08 LED LED 9 22300140BT09 CONECTOR CONNECTOR 10 22300140BT10 PANEL HORIZONTAL CLAPBOARD 1...

Page 27: ......

Page 28: ...Gala Gar S L C Jaime Ferr n 19 50014 Zaragoza SPAIN Tel 34 976 47 34 10 Fax 34 976472450 E mail info galagar com Web www galagar com...