Name of the boiler 

Boiler characteristics 

Ochag-2 

Ochag-3 

Ochag-5 

Ochag-6 

Geyser-9 

Geyser-15 

Vulkan-25 

(liters) 

10.

 

 Nominal diameter of 

couplings for 

connecting to the 

heating system (mm) 

25 

25 

25 

25 

32 

32 

32 

11.

 

 Class of protection 

against electric shock 

hazard 

12.

 

 Construction by 

moisture proofing 

degree 

IP X3 splash-proof 

13.

 

 Length (mm) 

250 

275 

320 

335 

360 

410 

460 

14.

 

 Weight (kg) 

0,85 

0,9 

1,05 

1,1 

5,0 

5,3 

5,7 

15.

 

 It is recommended to use the following types of liquids as heat-transfer agents for all of the “Ochag”, ”Geyser”, 

“Vulkan” electrode boilers of the “Firma “Galan” Joint-Stock Company which are listed in this table: 

 

“Galan-Potok” low-freezing liquid with special rust prevention components and additives against formation of 

scale and scum (freezing temperature: -40

º

 C, life expectancy: no less than 5 years, warranty period: 1 year) 

(hereinafter referred to as “low-freezing liquid”); 

 

Potable water (defined by the Sanitary Regulations and Rules No. 2.1.4.559-96), distilled water, snow melt 

water, rain water (filtered water)  the  specific  electric  resistance  (hereinafter referred to as “resistance”)  of 

which is no less than 1300 Ohm/cm at a temperature of +15

º

 C. 

 

ATTENTION! 

It is strictly forbidden to use  low-freezing liquids (antifreezes) such as “TOSOL”, “Arktika”, “Tvoy Dom”, etc. as heat-

transfer agents since they are not intended for a use by the electrode boilers. 

 

The “Firma “Galan” Joint-Stock Company regularly performs technological 

improvements of electric boilers, therefore their technical characteristics can slightly differ 

from characteristics resulted in the table above. 

 

Boilers construction 

 

 

Depending on the boiler power the electrode boilers produced by the “Firma “Galan” 

Joint-Stock Company fall into the following categories: 

 

Single-phase electrode boilers (“Ochag-2”, “Ochag-3”, “Ochag-5”,  and 

“Ochag-6” electrode boilers); 

 

Three-phase  electrode boilers (“Geyser-9”, “Geyser-15”,  and  “Vulkan-25” 

electrode boilers). 

 

Single-phase electrode boilers consist of the following components: 

 

Metal case with  inlet and outlet connections  (a  case functions  as the second 

electrode and ionization chamber); 

 

Rod electrode with current lead and hermetic electric bushing insulator; 

 

Two terminal groups with protective housings (phase terminal is located at the 

bottom of the single-phase electrode boiler; neutral wire terminal and ground 

wire terminal are on the side of the single-phase electrode boiler).  

 

Three-phase electrode boilers consist of the following components: 

 

Metal case with inlet and outlet connections (a case functions as ionization 

chamber); 

 

Base on which three electrodes with current leads and hermetic electric bushing 

insulators are installed; 

 

Terminal group with protective housing. 

 

The operating principle is the same for all electrode boilers. It is discussed below.   

 

Advantages of the electrode boilers 

 

The electrode boilers of  the “Firma “Galan” Joint-Stock Company are 2-3 times 

cheaper than the boilers of the same power produced by other manufacturers and have the 

following significant advantages: 

 

Significant energy conservation is achieved by high electrode boilers efficiency 

which  reaches 98%. By this indicator electrode boilers surpass the  existing 

Summary of Contents for Ochag-2

Page 1: ...OCHAG GEYSER VULKAN ELECTRODE BOILERS OPERATION MANUAL...

Page 2: ...d by the Firma Galan Joint Stock Company 11 Filling the heating system with heat transfer agent 15 Correcting procedure 16 Preventive maintenance Washing of the heating system 17 Visual examination of...

Page 3: ...ocess of installation of the heating system and boilers and in the course of starting further operation and usage of the electric boilers we convincingly ask you to familiarize yourself attentively wi...

Page 4: ...he Independent Noncommercial Organization on Certification of the Electrical Products 109052 Moscow ul Nizhegorodskaya 29 Voluntary certification Technical characteristics of the boilers produced by t...

Page 5: ...technical characteristics can slightly differ from characteristics resulted in the table above Boilers construction Depending on the boiler power the electrode boilers produced by the Firma Galan Join...

Page 6: ...ation compact size and light weight For example the weight of the boiler the power of which is equal to 6 kW comprises 1 1 kg and the weight of the boiler the power of which is equal to 25 kW comprise...

Page 7: ...automatic control system The electrode boiler cost does not include a cost of the automatic control unit With the exception of the operation manual for electromechanical model of the automatics which...

Page 8: ...the boiler and heating system including metal pipelines for the cold return pipe and hot heat transfer agent should be grounded The place of entering of the conductors into the building or constructio...

Page 9: ...rical installation of the boilers and automatics Three phase electrode boilers are connected to the four wire three phase power network the voltage of which is equal to 380 V Industrial frequency of t...

Page 10: ...unning on solid liquid or gas fuel Legend Laid on thermostat sensor Valve Filter mechanical mud settler Heat transfer agent drain valve Air drain valve Circulation pump power 70 or 100 W A Vertical se...

Page 11: ...on the basis of the specific situation the following temperatures are set on the Navigator temperature regulator Temperature on the outlet of the boiler a value belonging to the recommended optimal o...

Page 12: ...eak sensor water flooding sensor etc The Galan GSM cellular monitoring system of the heating equipment is used in conjunction with the Navigator control unit Perform the installation in accordance wit...

Page 13: ...ipping contactor size 2 up to 32 A 2 1 Automatic tripping contactor coil 220 V 2 2 Thermal relay contacts normally closed 3 Inlet temperature sensor laid on bimetallic thermostat 4 Outlet temperature...

Page 14: ...tic tripping contactor size 2 up to 25 A size 3 up to 40 A 2 1 Automatic tripping contactor coil 380 V 380 V 2 2 Thermal relay contacts normally closed 3 Inlet temperature sensor laid on bimetallic th...

Page 15: ...used for inhibition of corrosion and for scale dissolving The application of low freezing liquid saves from danger of unfreezing the heating system in the event of sudden power supply disconnection A...

Page 16: ...illed in the heating system Stir the dose of the salt solution and the water drawn off from the heating system carefully This mixture is filled in the heating system through the drain valve by means o...

Page 17: ...ost careful control over the boiler s automatic switching on and switching off It is inadmissible to switch on the boiler at presence of the frozen heat transfer agent in the system or in danger of fr...

Page 18: ...acks of the bushing insulators etc and for evaluation of electrodes wear In case of a wear comprises more than 40 the electrode electrodes should be replaced Traditionally this happens every 3 5 years...

Page 19: ...ed b Low freezing liquid as a heat transfer agent Add distilled water clear uncontaminated filtered rain water or snow melt water water the specific electric resistance of which significantly exceeds...

Page 20: ...and lubricating oils gasoline acetone turpentine bitumen roll roofing kerosene oils in the premises where the boiler is installed To dry clothing on the electric boiler shell Transportation and storin...

Page 21: ...e air locks 4 In due course the boiler wastes its power gradually under condition of using fresh water Presence of contamination rust and scale on the electrodes and on the internal surfaces of the bo...

Page 22: ...__________ _____ Performed tasks Executor Owner last name name and surname signature Name of the company performing the warranty repair Place of the seal Post and signature of the director of the com...

Page 23: ...__________ _____ Performed tasks Executor Owner last name name and surname signature Name of the company performing the warranty repair Place of the seal Post and signature of the director of the com...

Page 24: ...ce functions Date description of the maintenance functions License number address signature of the person responsible for performing maintenance functions Seal of the company organization which has pe...

Page 25: ...ery and sale certificate The electrode boiler meets the requirements of the Technical Specifications TS No 3468 001 17289826 02 Date of issue Seal of the Quality Department Sold Date of sale Place of...

Page 26: ...9 196 04 40 196 04 41 123098 Moscow m Shchukinskaya ul Marshala Novikova 2 building 1 http www galan ru e mail office galan ru MAXIMUM WARMTH MINIMUM COSTS OUR COMPANY PERFORMS THE DESIGNING INSTALLAT...

Reviews: