35. Read the instruction manuals of all the equipment completely and 
follow all the instructions. Everyone in your company who will work 
with the equipment must receive information, instruction, training 
and supervision with regards to the safe use of the equipment. 

 
 

The most current version of the safety regulations is always available in the download section of 
our website: www.galaxis-showtechnik.de 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PYROTEC PFS Pocket

Page 1: ...1 User Manual Galaxis Showtechnik PYROTEC PFS Pocket Firmware 1 3 Revision Date February 7th 2019 Batch No EUSP100101 USSP100101...

Page 2: ...essing the submenu Special functions 12 12 2 Acoustic Signals 12 12 3 Transmitting System ID and Teaching in devices 12 12 4 Setting the radio channel Frequency manually 12 12 5 PFS Pocket teach in an...

Page 3: ...damage unit aging as well as the wear and tear of the unit This fundamental thesis was the basic principle when writing these instructions 1 Smoking or naked flames are strictly prohibited within the...

Page 4: ...ing the rental period of the units Advise your staff that it is very important to report any possible damage of the units immediately Customers that have borrowed or rented the equipment are hereby in...

Page 5: ...ians and other persons Please also note that wind conditions can be totally different a few metres above the ground 23 Ensure that the firing of pyrotechnic effects can only be undertaken by the autho...

Page 6: ...9 Make sure the devices are switched off before connecting the e matches 30 When stripping the cable insulation of the igniters and connecting them you must ensure that they are not stripped so far ba...

Page 7: ...eryone in your company who will work with the equipment must receive information instruction training and supervision with regards to the safe use of the equipment The most current version of the safe...

Page 8: ...8...

Page 9: ...inated 7 Button and LED Arm Button to activate and deactivate the firing mode If the firing mode is activated the LED is illuminated 8 Battery Cover The batteries are located in this compartment under...

Page 10: ...en illuminated constantly in blue to indicate that the unit is on After switching on the device will be in normal mode The firing mode is switched off The PFS Pocket can only be switched off when the...

Page 11: ...wlessly 10 Switching on and off the deadman function Deadman means that this button DM must be held depressed at the same time as the firing channel button is depressed in order to transmit an ignitio...

Page 12: ...adio channel is set to 0 and the button 2 indicates the decade while the 3 indicates the unit position When for example the button 2 is pressed four times and the button 3 seven times so radio channel...

Page 13: ...values form For example Forming radio channel 383 from 283 by pressing the arrow button Hundreds 1 is not allowed Select a value from 0 to 5 in the tens before selecting the value 3 in the hundreds A...

Page 14: ...hen the two lower LEDs light up briefly for the second digit of the version number This is 0011 binary and this corresponds to 3 decimal The version number 1 3 results from the values 1 and 3 13 Radio...

Page 15: ...tated above had happened we are only liable if the defect was due to faulty workmanship or component parts The devices have been developed manufactured and tested to the best of our knowledge and beli...

Page 16: ...D V9X LMD400R Maximum radio frequency power transmitted 10 mW Channel Spacing 12 5 kHz Number of radio channels 360 458 0000 462 5000 MHz Modulation FM narrow band Frequency Shift 3 kHz Receiver Princ...

Page 17: ...nd contact details for requesting an EU declaration of conformity Galaxis Showtechnik GmbH Lohgerberstr 2 84524 Neu tting Germany Tel 49 8671 73411 Fax 49 8671 73513 Homepage www galaxis showtechnik d...

Reviews: