background image

 

 

NUMBER OF 

CONDUCTORS 

(Switch position) 

                                 
                                     CABLE TYPES 

 
 

¼” Mono (TS) Guitar / Line, ¼” Speaker, 1/8” Mono (TS) Line, 
Single RCA (use only the L (Mono) jacks on CT), NL2 Speakon 
Cables (and 4 conductor NL4 Speakon connectors wired for 2 
conductor service), and 2 conductor adapter cables that have 
mismatched connectors of the above types. 

 

Stereo (TRS) ¼”, Stereo (TRS) 1/8”, Most XLR Mic cables, XLR 
to TRS Adapters, Stereo (TRS) ¼” or 1/8” to Stereo (L&R) RCA 
Adapters, and other 3 conductor adapter cables that have 
mismatched connectors of the above types. 

 

NL4 Speakon Cables, Stereo (L&R) RCA, Some XLR Mic 
Cables (if the #4 shell conductor is used) 

 

DIN (MIDI) cables (some may be wired to use only 3 conductors 
of the 5 available) 

 

4.

 Indications: As the Selector Switch is rotated from the OFF 

position, the Green LED will blink twice to indicate the CT is ready 
to test. The Red LED will then light momentarily to indicate the 
cable is being tested. If the cable fails the test, the Red LED will 
remain lit. If the cable passes the test, the Red LED will go out and 
the Green LED will light. At this point you may want to check for 
intermittent problems by flexing or wiggling the cable. Be aware 
that cables can become intermittent because of wiring problems or 
failure of the connector contacts. Any change in the LED 
indications, even if only momentary, means that the cable has an 
intermittent problem and cannot be relied upon.

5. 

Advanced Tests: Most of the standard audio cables will test 

either Pass or Fail according to the indications described above. 
However, there are some alternative indications given for Pass and 
Fail for certain cables. The chart below describes some of these 
cables and what indications to expect.

3

Summary of Contents for JIB/CT

Page 1: ......

Page 2: ...le of Contents 1 Operation 2 2 Connections 2 Select Test 2 Indications 3 Advanced Tests 3 Other Special Cables 4 Custom Cables 5 Warranty 7 Registration Card Back Cover Introduction Battery Installati...

Page 3: ...this cable good or bad A unique computer controlled circuit tests the cable 200 times per second which allows the CT to detect and display intermittent problems that other cable testers fail to catch...

Page 4: ...e All of the connectors on the A side are duplicated on the B side except for the XLR jacks where the A side has a Female XLR and the B side has a Male XLR CAUTION Do not connect the CT to any audio d...

Page 5: ...the OFF position the Green LED will blink twice to indicate the CT is ready to test The Red LED will then light momentarily to indicate the cable is being tested If the cable fails the test the Red LE...

Page 6: ...CA R S to both RCA Shields A steady Red or Green LED indicates a failure for this cable If a steady Red LED is shown try reversing the L R RCA plugs some are unmarked XLR Mic 3 If Green and Red LEDs b...

Page 7: ...7 Custom Cables The CT is designed to test industry standard and commercially available cables and adapters The CT may not give accurate results for cables wired otherwise 5 NOTES...

Page 8: ...6...

Page 9: ...ue you to an RMA Return Merchandise Authorization which will need to be applied to the returned item Under no circumstances should you return your unit to the factory without receiving an RMA or writt...

Page 10: ...8 GALAXY AUDIO 601 E Pawnee Wichita KS 67211 316 263 2852 800 369 7768 Fax 316 263 0642 www galaxyaudio com Specifications subject to change without notice...

Page 11: ...y Audio better serve you _________________________________ _________________________________ _________________________________ _________________________________ __________________________________ ____...

Page 12: ...PLACE STAMP HERE GALAXY AUDIO P O BOX 16285 WICHITA KS 67216 0285...

Reviews: