background image

- 4 -

User Manual

Calibration

1.   When the scale is normal weighing mode, press and hold MODE key for about 6 seconds till it 

displays a required calibration weight. CAL weights required for different capacities are as below:

 

 

1kg/2lb scale - 500g or 1kg

 

 

5kg/11lb scale - 1kg or 2kg or 5kg

 

 

10kg/22lb scale - 2kg or 5kg or 10kg 

     Press MODE key to switch between the CAL weights, press TARE key to confirm, now the LCD will 

first display “CAL” then flash displaying the weight value.

2.  Now put the corresponding weights on the scale platter, after a few seconds when the inner code 

gets stable, the scale will display “PASS” and back to normal weighing mode.

3.  Remove the weights from the scale, now calibration has been finished.  

 
If any wrong operation happens during the calibration, the scale will display “Err”, then auto power 
off. Power on the scale again and repeat the above calibration steps.  
 
If you need to exit the calibration mode, press ON/OFF key to power off the scale.

Care Instructions

•  Place your scale on a hard, flat surface, to ensure the greatest accuracy and repeatability.
•  Clean your scale with a damp cloth but do not allow water to get inside the scales.
•  Do not use chemical abrasive cleaners to clean the scales.
•  Do not allow your scale to become saturated with water as this can damage the electronics.
•  Do not store the scale in an upright position when not in use.
•  Remove batteries if the scales are not being used for extended periods of time.
•  Treat your scale carefully, because it is a precision instrument.