GB1200 User Manual 

-  - 

11

rotate. 
2. Display Err1 and rotate. 

damaged. 
2. Phase position 
generator goes wrong 
and main board is 
damaged. 
3. Power supply voltage 
is much lower. 

panel. 
2. Adjust photoelectric tube 
shelf, replace main board. 
3. Boost voltage. 

Display 

Err2 

and 

rotate. 

1. Do not install the 
wheel. 
2. Only install rim but not 
tire. 
3. Temperature indoors 
is much lower, wheel 
inertia is not good. 

1. Install wheel. 
2. Install tire. 
3. Make sure that temperature 
indoors is more than 5 .

 

Display 

Err3 

Unbalance amount of 
wheel is much greater. 

Replace wheel or self-calibrate 
over again. 

Display 

Err4 

1. If reversal, phase 
position is connected 
incorrectly. 
2. If corotation, the 
position of sensor goes 
wrong. 

1. Change the phase sequence 
of three phases. 
2. Adjust the position again or 
replace it. 

Display Err7 

1. Memory is damaged. 
2. Signal loses. 

1. Replace X24C45. 
2. Self-calibrate over again. 

Only display invalid value 
00-00. 

1. Memory X24C45 is 
damaged. 
2. Lead wire of sensor 
breaks or is loose 
contact. 
3. Memory value loses. 

1. Replace it 
2. Connect over again. 
3. Input over again. 

The value of changed range 
every rotation is more than 5g. 

1. There are sundries in 
the tire. 
2. Sensor is affected 
with damp. 
3. The machine is place 
unsteadily. 
4. Harmful flow disturbs 
the machine such as 
electric portable drill and 
electric welding 
machine. 

1. Replace tire. 
2. Drying it and adjust again. 
3. Tighten fang bolts. 
4. Eliminate disturb and try 
again. 

The value of changed range 
every rotation is more than 
dozens of grams. 

1. There are sundries in 
the tire. 
2. Main board or power 
panel goes wrong. 
3. Sensor is placed 
unsteadily. 
4.  Outer power voltage 

1. Replace tire. 
2. Replace it. 
3. Check sensors and 
connecting line. 
4. Examine and repair or install 
the manostat. 

Summary of Contents for GB1200

Page 1: ...WHEEL BALANCER ITEM NO GB1200 GALAXY AUTO SERVICE EQUIPMENT CO LTD www galaxyauto biz...

Page 2: ...ree kinds of aluminum alloy rim Balancing precision is up to 1g balancing time is very short Having self calibration and automatic diagnostic functions 1 3 Technical data Fit for model 1200 downwards...

Page 3: ...erator should stand on both sides of the machine and non operator cannot stand nearby Do not exceed the using range of the machine during the operation process All the electric appliances are installe...

Page 4: ...with hands and do not press the keys using clamp and any other sharp things 4 WHEEL BALANCING OPERATION PROCESS 4 1 Electrical connection Open the power switch and then display the memory logo on the...

Page 5: ...2 2 Tire mounting with special flange Install the flange on the adapter tighten it with bolt Fix the screw mandrel on the main shaft Select the proper cone to fit over on the main shaft Tighten with l...

Page 6: ...reduces Until display the value D that is measured 4 4 Balancing modes According to wheel material and rim structure select different balancing modes and the position of balancing weight is also plac...

Page 7: ...artup key START automatic brake is displayed in 8 seconds show in Fig 1 40 is unbalancing value inside the tire 10 is unbalancing value outside the tire 2 Rotate the tire slowly when all the inner ind...

Page 8: ...tion Select the better tire to self calibrate input the correct dimension or else result in calibrating inaccurately 5 1 1 Self calibrating with a tire balanced 1 First press the keys R START the disp...

Page 9: ...the main shaft and the tire can be balanced with many lead blocks 1 The tire is not standard or there are sundries in the tire 2 Memory values dis and SFA do not adjust well 3 The value that is displa...

Page 10: ...Fig 3 Fig 3 Standard Memory Correcting value 100g of inner of static balancing 4 Then press the key as Fig 4 shown if the value displayed is not correct press the keys and of width dimension L and ad...

Page 11: ...ain or replace it Display Err7 1 Memory is damaged 2 Signal loses 1 Replace X24C45 2 Self calibrate over again Only display invalid value 00 00 1 Memory X24C45 is damaged 2 Lead wire of sensor breaks...

Page 12: ...ror is more than 10g 1 The inner hole of wheel is not regular 2 Adapter is installed improperly 1 Replace the wheel 2 Check the assembly surface over again Self calibration displays Err8 1 Power panel...

Page 13: ...GB1200 User Manual 13 Steps 1 Loosen nuts 2 Drying sensors 3 First tighten nut then tighten nut 4 First tighten nut then tighten nut Caution The screw mandrel cannot touch the hole edge in the board...

Page 14: ...Number Name Quantity TD01 Lockwasher bolt 1 TD02 Calipers 1 TD03 Balancing plier 1 TD04 Screw mandrel 1 TD05 Flange 1 1 TD06 Flange 2 1 TD07 Cone 1 1 TD08 Cone 2 1 TD09 Cone 3 1 TD10 Cone 4 1 TD11 Con...

Reviews: