background image

10

 

 

Exploded Views                                                                             

 

 

 

 

 

 

No. 

Part Name(Chinese) 

Part Name(English) Part 

No. 

Qty. 

Remark 

脚垫黑

 XD1710-148 

Rubber Foot 

1800318 

 

折弯底板

 GSB-01 

Machine Base 

1000402 

 

直纹把手

 M6-18-10 

Handle Screw 

1000569 

 

定位块

 GSB-03 

Metal sheet 

1000018 

 

热箍固定支架

 CG-03 

Holding Block 

1000017 

 

肘夾固定板

 GB-01 

Holding Base 

1000015 

 

杯垫护盖

 GB-Y102 

Heater Cover 

1000019 

 

柱形门磁(车牙加工)

MC-0627  Magnet switch 

1800620 

 

调压螺杆(无牙)

SSL-01 

threaded rod

 

1800158 1   

10 

快速夹钳

 Clamp-01 

Clamp 1000421 

 

11 

手柄球

 GS-JZN039 

Ball Shape Handle 

1800620 

 

12 

推滑块

C GB-Y101 

Pressure Block 

1000016 

 

Summary of Contents for GS-202

Page 1: ...xamination and repair Incorrect assembly or repair could increase the risk of fire electric shock or injury to persons when the equipment is used 7 This appliance is not intended for use by persons in...

Page 2: ...5 Operating Instructions 6 9 Connecting the System 6 Turning the System On 6 Adjusting the Temperature 7 Adjusting the Time 7 Counter Setting 8 Switch Between F C 8 Temperature Clibration 8 Adjusting...

Page 3: ...oz 15oz etc mug 12oz Latte shape mug heater 17oz latte shape mug heater Power 120volt 300W 2 7Amps 300W 2 7Amps Power 240volt 300W 1 4Amps 300W 1 4Amps Temperature Range Max 200 392 Max 200 392 Time R...

Page 4: ...4 Machine View...

Page 5: ...5 Control Panel Guide...

Page 6: ...be as short as possible and not less than 12 gauge Heavy duty cords are recommended CIRCUITS that have less than 10 amps or that have other high demand equipment or appliances especially more than one...

Page 7: ...e Control Panel the second time TEMPERATURE 2 lights located in the display will illuminate indicating you are in the adjust temperature mode 3 4 Next press the button located to the bottom of the Mod...

Page 8: ...he value The counter setting range can be set from 0 99999 6 1 Press and hold the button then press model select button F C lights located in the display will illuminate indicating you are in the adju...

Page 9: ...uipment has reached the designated temperature1 position the blank mug inside and proceed to press 6 2 After pressure handle closed heater will heat up from temperature1 to temperature 2 then time sta...

Page 10: ...02 1 3 M6 18 10 Handle Screw 1000569 1 4 GSB 03 Metal sheet 1000018 1 5 CG 03 Holding Block 1000017 1 6 GB 01 Holding Base 1000015 1 7 GB Y102 Heater Cover 1000019 1 8 MC 0627 Magnet switch 1800620 1...

Page 11: ...over 1200446 1 18 8A L1080271504 01 Fuse 1800348 1 19 GSK G03 Circuit Breaker 1800354 2 20 RK1 01 On off switch 1800346 1 21 IEC DB 14 1 socket 1800344 1 22 TB1503L Terminal Block 1800345 1 23 DX146 1...