background image

10

The cover lifter that fits the following spas needs 915mm rear clearance:

Orion, Hydra, Lyra, Andromeda, Columba and Solarium.

If Sinking Your Spa / Tight Spaces

If you are planning to sink your spa pool and still want a cover lifter, or if you have very limited 
clearance space, we have a cover lifter that requires only 200mm of rear clearance. This will also 
fit our Lunar hot tub. Talk to your sales consultant for more information.

Cover Lifter Must be Installed Before the Spa is Filled 

It’s essential that you assemble your cover lifter before delivery as it needs to be installed before 
the spa is filled with water. If you have opted for a premium delivery package, this service is 
likely included - check with your sales consultant if unsure. 

Spa Model

Width

Length

Height

Dry 

Weight

Water 

Capacity

Power 

Requirement

Rosa

1640mm

2000mm

820mm

240KG

798L

10 Amps

Juno

2000mm

2000mm

820mm

305KG

1,080L

10 Amps

Lunar*

1980mm

1980mm

920mm

303KG

820L

10 Amps

Ceres

1500mm

2000mm

740mm

241KG

720L

15 Amps

Venus

1740mm

2000mm

820mm

304KG

540L

32 Amps

Aquila I

2000mm

2000mm

820mm

290KG

960L

15 Amps

Aquila II

2000mm

2000mm

820mm

290KG

960L

32 Amps

Jupiter

2000mm

2000mm

820mm

275KG

1,080L

15 Amps

Orion

2120mm

2120mm

920mm

391KG

1,350L

32 Amps

Hydra

2120mm

2120mm

920mm

349KG

1,480L

32 Amps

Capella

1740mm

2000mm

820mm

314KG

710L

32 Amps

Draco I

2000mm

2000mm

820mm

334KG

960L

15 Amps

Draco II

2000mm

2000mm

820mm

334KG

960L

32 Amps

Lyra

2120mm

2120mm

920mm

376KG

1,160L

32 Amps

Andromeda

2300mm

2300mm

920mm

413KG

1,490L

32 Amps

Columba

2180mm

2180mm

920mm

437KG

1,380L

32 Amps

Solarium

2180mm

2180mm

950mm

440KG

1,350L

32 Amps

* Lunar is a round tub spa

Summary of Contents for Rosa

Page 1: ...SPA PRE DELIVERY GUIDE...

Page 2: ...allation of a Galaxy Spa There are a number of important steps decisions and actions that must be taken prior to delivery day to ensure a smooth delivery Please read through this guide thoroughly At t...

Page 3: ...tallation 13 Foundation Requirements 14 Concrete Foundation 14 Decking 14 Heat Pump Foundation 14 Spa Steps 14 Drainage 14 Above Ground and In Ground Options Building Regulations Consent 15 Building C...

Page 4: ...ractical option so different methods of delivery can be explored such as a helicopter or crane For spa pools that need to reach over a house or from a distance greater then 7m a crane is a great optio...

Page 5: ...oard mains Splashing while swimming is all part of the experience Does your positioning offer adequate drainage Is there enough room within the total foundation for other accessories such as steps hea...

Page 6: ...minimum height of 760mm and is fitted with a hard lockable cover All Galaxy Spas excluding the Juno meet these requirements and do not require fencing If any permanent structures will be near the spa...

Page 7: ...e sunniest and most sheltered spot you can place your spa Out of the wind and in the sun is ideal and not too far from the house for those chilly nights Heat pump Electricity Your heat pump must be pl...

Page 8: ...500mm around the spa as a service area Panels may need to be removed during servicing so there needs to be enough room for a technician to work 500mm is the absolute minimum View This is where you are...

Page 9: ...gram on page 14 Foundation Requirements Cover Lifter A cover lifter is an accessory that attaches to the spa pool and supports removing the cover The benefits of a cover lifter are twofold it takes th...

Page 10: ...sultant if unsure Spa Model Width Length Height Dry Weight Water Capacity Power Requirement Rosa 1640mm 2000mm 820mm 240KG 798L 10 Amps Juno 2000mm 2000mm 820mm 305KG 1 080L 10 Amps Lunar 1980mm 1980m...

Page 11: ...over locks in use The cover locks have multiple functions working to help keep the warmth in your spa keeping the spa cover on in windy weather while also being an important safety feature and keeping...

Page 12: ...ous section to see where the heat pump unions are positioned Required Materials 40mm of PVC pressure pipe enough to suit the plumbing configuration of where your heat pump sits in relation to the swim...

Page 13: ...ber 4 Close the two shut off valves at either end of the heat pump unions 5 Plumb the correct unions from the heat pump to the spa 6 Purge air from the heat pump by loosening the outlets until water s...

Page 14: ...oundation for this as well Spa Steps Steps also need a flat level foundation to sit on Steps do need to remain moveable so do not fix these in place 2 Tier Steps Length 600mm Width 580mm Height 300mm...

Page 15: ...Spa meets NZ height and cover regulations The Juno model requires fencing as it is 740mm in height which does not meet the minimum 760mm height regulations In Ground Installation Sinking Where you wan...

Page 16: ...equires an outdoor 10A electrical socket A 15A spa requires an outdoor 15A electrical socket Note It is not possible to plug a spa pool into a 10A standard house socket An RCD Residual Current Device...

Page 17: ...ocks and lower gently onto the foundation Power cord Power cord Installation Guides Installation guides for your specific control system can be found on the Support page on our website Please ensure y...

Page 18: ...10A 15A Spas Cord Location Lunar Control Box Control Panel Drain Valve Ceres Control Box Control Panel Drain Valve Rosa Control Box Control Panel Drain Valve Juno Control Box Control Panel Drain Valv...

Page 19: ...19 Aquila I Jupiter Draco I Control Box Control Panel Drain Valve Heat Pump Union Control Box Control Panel Drain Valve Control Box Control Panel Drain Valve...

Page 20: ...a II 32A Spas Hard Wire Location Orion Capella Control Box Control Box Control Panel Control Panel Drain Valve Drain Valve Heat Pump Union Control Box Control Panel Drain Valve Control Box Control Pan...

Page 21: ...I Control Box Control Box Control Panel Control Panel Drain Valve Drain Valve Heat Pump Union LYRA ANDROMEDA Control Box Control Panel Drain Valve Control Box Control Panel Drain Valve Heat Pump Union...

Page 22: ...22 COLUMBA SOLARIUM Control Box Control Box Control Panel Control Panel Drain Valve Drain Valve Heat Pump Union Heat Pump Union...

Page 23: ...23 JUNO VENUS JUPITER ROSA CERES LUNAR AQUILA I ORION AQUILA II Recommended Cable Input Location...

Page 24: ...24 COLUMBA SOLARIUM LYRA ANDROMEDA DRACO I CAPELLA HYDRA DRACO II...

Page 25: ...l groove under the corner panels of your cabinetry which the cord can fit under No drilling through the cabinet is required A hole can be drilled into the cabinetry attaching a grommet if this is pref...

Page 26: ...pumps to run for a few minutes with the cover off so the chemicals can mix Step Eight 4 6 hours after you have added your chemicals test your water use the testing strips supplied in the kit to analy...

Page 27: ...if needed Notes 4 Foundations complete Notes 5 Electrical concealed power feed complete If chosen Notes 6 Delivery booked Notes 7 Electrician booked if needed Notes 8 Remove packaging find cover locks...

Page 28: ...GS0002 08172021 0800 459 772 galaxyspas co nz...

Reviews: