background image

34

Foam inhibitors can suppress foam, but cannot remove soap from the water. Soap is very difficult to remove from the water because soap is not oxidized by any
chemical added to the spa. Only ozone can oxidize soap.

Eventually the soap build-up in the water will be concentrated, resulting in an unclean feeling on the bather’s skin, which is impossible to remedy. When this occurs, it’s
time to drain and refill the spa. Depending on the soap input, the water should last about 4 months before needing to be drained.

MONARCH

®

OZONE SYSTEM

The Monarch high output ozone system is the only ozone purification system approved for installation in your Caldera

®

Spa. The Monarch ozone system utilizes Corona

Discharge (CD) technology to produce a higher concentration of ozone than is produced by competing ultraviolet light (UV) ozone systems.

The Monarch high output ozone system unit offers less-visible installation and is less susceptible to the effects of freezing temperatures because it is mounted under the
skirt. To access it for inspection, remove the equipment compartment door to check the unit operation (this is usually done prior to disconnecting the power to the spa
before draining). Simply listen for the buzz of the transformer to verify operation of the Monarch high output ozone system.

The Monarch high output ozone system greatly enhances the quality of the spa water when used to supplement the spa owner’s regular water maintenance program.
Contrary to some information circulated throughout the pool and spa industry regarding ozone systems, ozone 

CAN’T

be used as a single-source sanitizer, water

clarifier, anti-foamer, and mineral chelating agent. Watkins

®

Manufacturing Corporation recommends that a chemical maintenance program based on recognized and

documented industry standards still be followed when using an ozone purification system to assure water sanitation and the highest quality purified water.

Cleaning the Ozone Injector

On occasion, a mineral build up may clog the ozone injector, causing a lack of flow or low flow, of ozone bubbles. To prevent this, refer to the following instructions to
clean the injector:

1. Disconnect power to the spa.

2. Access the equipment compartment. 

3. Locate the ozonator in the equipment compartment and unplug the ozonator from the control box.

4. Place 16 ounces of white vinegar into a container such as a cup or bucket. Place the container on the equipment compartment floor. NOTE: White vinegar will not

damage any of the spa components.

5. Carefully loosen the long tubing to the bottom of the ozonator. 

A liquid substance may be found inside the tubing. If a liquid substance is present, BE

CERTAIN NOT TO COME INTO CONTACT WITH THE LIQUID (SEE WARNING BELOW)

.

6. Place the end of the tubing into the vinegar, making certain that the end of the tubing sits at the bottom of the container.

7. Reconnect power to the spa.

8. Run the spa until all 16 ounces of the vinegar are gone. This should allow an ample flow of vinegar to be run through the injector and clear the blockage.

9. Disconnect power to the spa.

10. Remove the empty cup or bucket.

11. Reinstall the tubing to the bottom of the ozonator.

12. Plug the ozonator into the control box.

13. Close the equipment compartment door.

14. Reconnect power to the spa.

The Monarch ozone system is practically maintenance-free because it is located within the spa’s equipment compartment. If bubbles are appearing at the spa’s heater
return, but the water is not as clear as usual, then the operation of the ozone generator should be checked. Carefully open the equipment compartment door (remember
to use care, as power is still connected to the spa) and verify that the CD tube and its transformer are energized (a slight buzz will be emitted from the ozone generator
housing). If a slight buzz or hum is not audible, verify that the generator is completely plugged into the spa’s control box.

If the unit is plugged in and power is connected to the spa, then the fuse (for the ozone generator) should be checked.

WARNING:

Contact your Caldera

®

Spa Dealer if your spa requires troubleshooting beyond the scope of this manual. Monarch ozone systems should only be serviced

by a qualified technician.

WARRANTY NOTE:

Cleaning of the ozone injector is not covered under the warranty. Refer to the Ozone section of this manual for ozone injector cleaning instructions..

DOS AND DON’TS

• DON’T use swimming pool (muriatic) acid to lower pH.
• DON’T splash pH increaser additives on the siding.

WATER QUALITY AND MAINTENANCE

Nitric acid accumulates in the air lines of the ozonator and injector. Nitric acid
will cause severe chemical burns if direct skin contact is made, so always
wear protective gloves, glasses and clothing when working on the ozonator
or injector lines. To prevent inhalation or ingestion of the nitric acid, DO NOT
blow or inhale with your mouth to any of the adapters, fittings or tubing of
the ozonator or injector air lines.

WARNING

WARNING

Summary of Contents for Geneva

Page 1: ...GenevaTM Niagara Tahitian Elation AspireTM Utopia Aquatic Melodies Series Owner s Manual...

Page 2: ..._________________________ SPA MODEL SERIAL NUMBER ______________________________ COVER SERIAL NUMBER ____________________________________ In most cities and counties permits will be required for the i...

Page 3: ...PERATING INSTRUCTIONS Control Panels 20 Locking Features 20 Main Control Panel Buttons and Display 21 Auxiliary Control Panel Buttons 22 Aquatic Melodies Surround Sound System 23 EQUIPMENT COMPARTMENT...

Page 4: ...uctions per electrical configuration 230 volt permanently installed models A ground terminal is provided on the terminal block located inside the control box To reduce the risk of electric shock conne...

Page 5: ...or with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using spa Unclean water Keep the water clean and sanitiz...

Page 6: ...any problems can easily be diagnosed over the telephone by an Authorized Service Technician SAVE THESE INSTRUCTIONS SITE PREPARATION You probably have a spot picked out for your new spa whether it s i...

Page 7: ...er regularly to ensure proper levels of sanitizers pH and other water care requirements Drain clean and refill your spa with fresh water on a regular schedule and in accordance with this owner s manua...

Page 8: ...ria Jet 11 Diverter Valve 12 Suction Screen 13 Light 14 Ozone Jet 15 Control Panel 16 Pillow 17 Filter Compartment 18 Auxiliary Panel 19 Grab Rail 20 Atlas Neck Jet Valve 21 Atlas Neck Jet Pillow 22 T...

Page 9: ...Air Jet 5 MagnaTM Jet 6 VersaSsage Jet 7 OrbiSsageTM Jet 8 Whirlpool Jet 9 Euphoria Jet 10 Diverter Valve 11 Suction Screen 12 Light 13 Ozone Jet 14 Control Panel 15 Pillow 16 Filter Compartment 17 Au...

Page 10: ...TM Jet 9 Whirlpool Jet 10 Euphoria Jet 11 Diverter Valve 12 Suction Screen 13 Light 14 Ozone Jet 15 Control Panel 16 Pillow 17 Filter Compartment 18 Auxiliary Panel 19 Grab Rail 20 AcquarellaTM Waterf...

Page 11: ...zone Jet 11 Diverter Valve 12 Suction Screen 13 Light 14 Pop up Speakers 15 Control Panel 16 Pillow 17 Filter Compartment 18 Grab Rail 19 AcquarellaTM Waterfall Valve 20 Auxiliary Control Panel 21 Atl...

Page 12: ...uphoria Jet 9 Ozone Jet 10 Diverter Valve 11 Suction Screen 12 Light 13 Pop up Speakers 14 Control Panel 15 Pillow 16 Filter Compartment 17 Grab Rail 18 AcquarellaTM Waterfall Valve 19 Auxiliary Contr...

Page 13: ...elf is already connected to the neutral bus bar 4 Connect the 10 AWG BLUE wire from the subpanel 30 amp breaker terminal L1 to TB 1 terminal 2 5 Connect the 10 AWG RED wire from the subpanel 30 amp br...

Page 14: ...ge wire than stated ELECTRICAL INSTALLATION System Ground Terminal GRD WARNING THE EXACT PHYSICAL LOCATION OF THE TERMINALS ON THE GFCI BREAKER WILL VARY BETWEEN MANUFACTURERS CONNECTING THE HOT WIRE...

Page 15: ...is manual 4 Adjust Total Alkalinity TA to 125 ppm Calcium Hardness CH to 150 ppm then spa water pH to between 7 4 and 7 6 These procedures are listed in the Water Quality and Maintenance section IMPOR...

Page 16: ...valve on the inside wall of the spa ATLAS NECK JET VALVE The GenevaTM Niagara and Elation spas are equipped with 4 directional neck jets located in the EcstaSeatTM The flow of the neck jets is regulat...

Page 17: ...rotation can be changed by rotating the jet faceplate from a full stream to shutting the jet completely off For cleaning or replacement instructions see VersaSsage OrbiSsage Jets Maintenance section T...

Page 18: ...Jet Pump 2 Jet System 2 Located in Ultra Massage seat front right 2 Euro Directional jets 2 VersaSsage jets 2 OrbiSsage jets Activates right side diverter Right Side Jet System 1 1 Whirlpool jet on ri...

Page 19: ...et System 2 Located in Ultra Massage seat front right 2 Euro Directional jets 2 VersaSsage jets 2 OrbiSsage jets Activates right side diverter Right Side Jet System 1 1 Whirlpool jet on right wall Acq...

Page 20: ...nt right 2 Euro Directional jets 2 VersaSsage jets 2 OrbiSsage jets Activates right side diverter Right Side Jet System 1 1 Whirlpool jet on right wall Acquarella Waterfall Jet Pump 2 Jet System 2 Loc...

Page 21: ...System 1 AcquarellaTM Waterfall 6 Sole Soothers in back center Located in Ultra Massageseat 2 Euro Directional jets 1 VersaSsage jets 2 OrbiSsage jets 6 Sole Soothers Combination Jet System Jet Pump...

Page 22: ...6 Sole Soothers in footwell 2 VersaSsage jets on front left wall Located in LumbarSsage seat front right 4 Euro Directional jets 2 VersaSsage jets Combination Jet System Jet Pump 1 diverter in mid po...

Page 23: ...the lock will remain in place SPA LOCK The Spa Lock feature deactivates all of the functions of the control panel It is generally used to prevent unwanted use of the spa To activate the Spa Lock press...

Page 24: ...t temperature display will increase by one degree every half second To decrease the set temperature of the spa water press the TEMP Each time the button is pressed the set temperature display will dec...

Page 25: ...minimized When the outside temperatures begin to cool the Summer Mode timer should be turned to the OFF position the summer mode icon on the main control panel shut off This is the efficient 24 hour...

Page 26: ...available station in radio mode NOTE Five seconds after the last button is pressed the auxilary panel defaults back to normal spa mode AQUATIC MELODIES MUSIC SYSTEM Available on Elation and Aspire The...

Page 27: ...MENT 4 5 2 3 4 4 4 4 6 7 1 Jet Pump 1 2 Jet Pump 2 3 Ozone Injector 4 Unions 5 Air Blower 6 Light 7 Temperature Sensor 8 Pump Drain Plug Air Blower available on GenevaTM Niagara and Tahitian spas only...

Page 28: ...25 A B C D EQUIPMENT COMPARTMENT A AdventTM System Control Box B EnergyPro Circulating Pump C EnergyPro Flow Through Heater D Monarch CD Ozone Generator E SpaGloTM LED Light Controller E CONTROLS SIDE...

Page 29: ...era dealer Refer to the back of this manual to determine the appropriate size for your spa DIVERTER VALVE MAINTENANCE If your spa s diverter valves become difficult to turn it is likely that sand or g...

Page 30: ...t dry vacuum or a sponge 3 It will be necessary to remove all water from the interior plumbing 4 Remove the filter lid floating weir basket filter cartridge and standpipe Insert a shop vacuum hose int...

Page 31: ...surface NEVER USE HARSH CHEMICALS Damage to the shell by the use of harsh chemicals is not covered under the warranty IMPORTANT Some surface cleaners contain eye and skin irritants Keep all cleaners...

Page 32: ...ctions precisely Though chemicals protect you and your spa when used correctly they can be hazardous in concentrated form Always observe the following guidelines Allow only a responsible person to han...

Page 33: ...orrosive nature of the spa s water That s why calcium low water commonly known as soft water is not recommended It is very corrosive to the equipment and can cause staining of the spa shell C If the C...

Page 34: ...ed A weekly shock treatment is required The shock treatment quickly destroys any remaining contaminants while revitalizing the silver cartridge allowing the silver ions to continue to be released into...

Page 35: ...or chlorine Answers Bromine or biguanides will chemically react with the sanitizing action of the silver ions This will eliminate their beneficial sanitizing effect DOS AND DON TS DO check your MPS or...

Page 36: ...ally The greater the usage time or the bather load the faster the residual value is diminished SUPPLEMENTAL WATER MAINTENANCE Proper water sanitation and mineral balance pH control are absolutely esse...

Page 37: ...cup or bucket Place the container on the equipment compartment floor NOTE White vinegar will not damage any of the spa components 5 Carefully loosen the long tubing to the bottom of the ozonator A liq...

Page 38: ...ecifically not covered under the terms of the warranty Question When I open my spa I smell chlorine How do I get rid of this smell Answer There are two types of chlorine in your spa The first is the F...

Page 39: ...low pH or by water with levels of TA CH pH or sanitizer which are outside the recommended ranges DPD The preferred reagent used in test kits to measure the Free Available Chlorine Halogen Any one of...

Page 40: ...l include any operation of the spa other than in accordance with Watkins Manufacturing Corporation printed instructions or use of the spa in an application for which it is not designed specifically us...

Page 41: ...ptic harness Dirty Filter Low water level Pressure switch problem Temperature sensor problem Heater high limit thermostat tripped Temperature set too low Spa cover improperly positioned Dirty Filter S...

Page 42: ...39 NOTES...

Page 43: ......

Page 44: ...LLONS BS BS BS PER SQUARE FOOT VOLT OR AMP 3INGLE PHASE PROTECTED CIRCUIT g X g 5TOPIA ENEVA4 3QUARE FEET ALLONS BS BS BS PER SQUARE FOOT VOLT OR AMP 3INGLE PHASE PROTECTED CIRCUIT 5TOPIA 4AHITIAN 3QU...

Reviews: