Page 1: ...1 MANUAL INPUT MODULE INTRINSICALLY SAFE IMGALILEO MODC03B003 12 2020 Ver 06 Schedule Drawing Do not change without certification agency Notified Body approval...

Page 2: ...2 MANUAL INPUT MODULE INTRINSICALLY SAFE IMGALILEO MODC03B003 12 2020 Ver 06 Schedule Drawing Do not change without certification agency Notified Body approval...

Page 3: ...or organization of such changes or improvements 2020 Galileo Technologies All rights reserved Except as expressly provided herein no part of this manual may be reproduced for any purpose without the e...

Page 4: ...ation 9 5 1 Connection to the supply 9 5 2 Equipment operation 10 6 Fuse operation 11 7 Cleaning and decontamination 11 8 Equipment maintenance and service 12 8 1 Disconnecting circuits 13 8 2 Removin...

Page 5: ...Maintenance Troubleshooting Dismounting 1 2 Symbols Used This document contains symbols for the identification of warning messages and of informative messages Warning Messages You will find warning m...

Page 6: ...l summarizes the use of the following product Type MODC03B003 Input module intrinsically safe Picture is only a reference Warning Advertisement Read instruction s manual before operation Lisez des ins...

Page 7: ...o digital signal store and send by protocol Modbus RS485 Each channel could be settable by a jumper to read any analog signal before mentioned The Input Module intrinsically safe prevents the transfer...

Page 8: ...degree of Protection IP20 according to EN 60529 The Zener Barrier is secured to a DIN rail using a tab and screw Additionally a snap in spring mounting system and can be removed with an Allen to remov...

Page 9: ...f the conductor When using stranded conductors crimp wire end ferrules on the conductor ends Use only one conductor per terminal When installing the conductors the insulation must reach up to the term...

Page 10: ...ltage DC voltages and AC voltages of up to 1 MHz pass through the barrier without attenuation Any voltage above the rated voltage is clamped to the rated voltage until the current exceeds 40 mA at whi...

Page 11: ...nd the fuse cannot be replaced 7 Cleaning and decontamination For cleaning turn off the power to the unit and clean with a damp cloth Make sure that the unit is dry before turning the power back on DO...

Page 12: ...hould be used only under the specified operating conditions and must be protected against excessive dust and mechanical stress shock vibration etc Avoid high atmospheric humidity which can lead to con...

Page 13: ...isconnect the power supply Modbus communication first remove the M4 screw from tab with an Allen and then with a flat head screw driver by inserting the screw driver head in steel tab on the DIN rail...

Page 14: ...afety precautions The temperature should be maintained between 20 C and 70 C 4 F and 158 F Contamination must be prevented from entering the unit The environment should be dry and as free from vibrati...

Page 15: ...24VDC supply Communication Modbus RS485 Function This Input Module intrinsically safe transfers Analog signals from 4 20mA 0 10V PT1000 DI Convert to digital signal store and send by protocol Modbus...

Page 16: ...45 C Storage temperature 25 70 C Relative humidity max 80 without condensation Mechanical Specifications Protection degree IP20 Connection Screw Rising Cage Clamp max core cross section 3 mm2 mass ap...

Page 17: ...17 Co 1 5uF Lo 2 0mH Lo Ro 583uH Maximum safe voltage Um 250 V AC DC...