8.11 Connecting CAN-LOG
The CAN-LOG device is designed for CAN-bus data reading. It allows getting the data about:
-
total time of engine operation;
-
total mileage of a vehicle;
-
whole fuel consumption of a vehicle
since the date of the vehicle`s creation
;
-
fuel level in % or liters;
-
engine speed;
-
coolant temperature;
-
vehicle speed;
-
axle load.
The CAN-LOG support was added to secure compatibility with the installed board equipment. By
initial installation it is recommended to use the device built-in functions for CAN-bus operation
(section CAN-interface). Advantages of using built-in functions of the device:
-
no extra costs;
-
a possibility to scan the CAN-bus;
-
a possibility to read all CAN-bus data, and not just those listed for the CAN-LOG.
To connect the CAN-LOG you have to:
1.
Connect RXD, TXD,
GND contacts of the Terminal and RS232 TX, RS232 RX,
CAN-LOG’s mass
correspondingly.
2.
Configure RS232 port in the Terminal for operation with the navigator. It can be done by RS2320 6
command or in the Configurator on Settings\Digital inputs tab.
3.
Disconnect the Terminal built-in functions for operation with CAN-bus.
It can be done by
CANREGIME 0,250000,2000 command or in the Configurator on Settings\CAN tab .
4.
S
pecify the parameters transferred to the server (
Table 2. GalileoSky protocol tags
). HEADPACK OR
MAINPACK commands can also be used (section
Server exchange protocol settings
) or in the
Configurator on Settings/Track tab.
8.12 Connecting CUB5B indicator
The CUB5B indicator is a segment 8-bit
indicator, which can be connected to the Terminal using RS232
interface. It can display current sensors data, CAN-bus data, mileage
and so on.
Information updates every
second.
Connection:
1.
If the indicator was set to operate with other equipment, it is necessary to reset to factory
settings. If the indicator is new, it is unnecessary.
2.
Connect RXD, TXD, GND Terminal contacts and TX, RX and Ground contacts of the CUB5B
correspondingly.
3.
Configure RS232 port in the Terminal for operation with
indicator,
it can be done by RS2320 7
command or in the Configurator on Settings\Digital inputs tab .
4.
Choose the displayed parameter, it can be done by
CUB5
command or in the Configurator on
Settings\Digital inputs tab.