20.
05
Non Volatile Setup
Error 05 is a check of the non volatile variables. These are the set up variables which must remain
unchanged during a power failure. They remain constant unless changed by a diagnostic function.
They are checked (against their backup variables) both at startup (all non-vol variables checked)
and dynamically (one byte checked each call from main loop). If an error is found, the non volatile
variables are all reset to their default values and (if not found during startup) the system restarts.
06
Delivery variables lost
This is a startup check of the current/last delivery related variables. These variables are
overwritten with each new delivery, but in case of power loss, must be present between deliveries.
Unlike the non-vol variables, during deliveries, these are continually changing and are therefore
not checked dynamically. At startup, these are checked (for corruption of XRAM during power
loss) against their backup variables. If an error is found, the non volatile variables are all reset to
their default values.
07
Keyboard Error
This is a startup check of local or remote (input processor) DIP switch setting validity, and for the
presence of the relevant keyboards. This error is non-fatal error which serves as an audible
warning to reconfigure DIP switches or replace keyboards and restart the system.
08..09 Not used
Errors 08 and 09 are reserved.
Summary of Contents for Apollo 3000
Page 1: ...Apollo 3000 Set up Installation Parts Manual...
Page 2: ......
Page 4: ......
Page 15: ...11 Float Switch 89778 Float Swt Mtg Angle only 89749 Float Switch Bracket Assembly...
Page 26: ...22 Stage 1 Installation Procedure Sump Column Position Fig 2...
Page 27: ...23 file gme c docum pec apollo2 fig 2 manual doc Stage 1 Installation Service Area Spec Fig 3...
Page 28: ...24 Stage 1 Installation Procedure Mounting Positions Fig 4...
Page 29: ...25 Stage 3 Vent Box Installation Vent Box Position Sealing Spec Fig 5...