If
yes,
the
leading
edge
Load
cells
on
the
Main
platform
are
functioning
correctly.
If
no,
the
leading
edge
Load
cells
on
the
Main
platform
are
malfunctioning.
See
below
for
details
on
identifying
the
problem.
7.
Stand
on,
or
place
a
weight
on,
the
trailing
edge
of
the
Main
platform
and
look
at
the
Auto
Weighing
Configuration
screen
on
the
Scale.
8.
Did
the
Trailing
weight
value
increase
from
the
value
you
wrote
down?
If
yes,
the
trailing
edge
Load
cells
on
the
Main
platform
are
functioning
correctly.
If
no,
the
trailing
edge
Load
cells
on
the
Main
platform
are
malfunctioning.
See
below
for
details
on
identifying
the
problem.
Malfunctioning Load cells
If
you
have
found
malfunctioning
Load
cells
check
the
following:
Check
wiring
in
Junction
box.
Clear
all
debris
from
on
and
under
the
Weighing
Platforms.
Ensure
the
Lead
‐
on
and
Main
platforms
are
not
touching.
Check
all
cables
for
damage.
Check
all
Amphenol
plugs
are
clean
and
correctly
connected.
Then
complete
the
procedure
again.
Contact
your
supplier
if
you
have
continuing
problems.