Using The Energizer Controller
Energizer Voltage and Alarm
The energizer output is the default screen display mode. The zone indicator arrow
is highligh
ti
ng the energizer zone ( ) and the energizer output voltage is 7.3KV in
this case.
The quickscan bargraph display is also indica
ti
ng an output voltage of over 7KV.
Controller showing the energizer opera
ti
ng normally
If the energizer output voltage falls below the alarm level (default 3KV) then the
status LED will
fl
ash red, the energizer zone indicator will become highlighted and an
internal buzzer will sound on the energizer. The buzzer can be muted by pressing any
key on the controller, except when there is a sudden increase in fence load. In this
situa
ti
on the buzzer will
ti
me out a
ft
er 15 minutes (if the energizer has not already
been turned o
ff
).
Controller showing the energizer in output alarm