Gallagher 3E2488 M1200i Energizer User Manual
15
The alarm level can be adjusted or turned o
ff
by entering the setup mode (
). The zone which is currently ge
tti
ng setup will
fl
ash and will be highlighted by the
zone indica
ti
on arrow. You can move to setup the energizer zone by pressing the
naviga
ti
on bu
tt
ons (< or >). Pressing (+ or -) increases or decreases the alarm
level. The lower the alarm level, the lower the sensi
ti
vity. The energizer alarm can be
disabled by pressing (-) un
ti
l the display shows (- -). To exit the setup mode
wait 10 seconds or press the setup bu
tt
on (
).
Controller showing the energizer alarm setup at 3.0KV
Earth System Voltage and Alarm
View the earth system performance by pressing the naviga
ti
on bu
tt
ons (
<
or
>
) while
the energizer is opera
ti
ng un
ti
l the zone indica
ti
on arrow is highligh
ti
ng the earth
zone ( ). The earth voltage will be displayed if a reference earth stake is installed.
If there is no reference earth it will display 0.0KV. If the earth voltage rises above
the earth alarm level (default 0.5KV) the status LED will
fl
ash red, the earth zone
indicator will be highlighted and the internal buzzer will sound on the energizer. The
buzzer can be muted by pressing any key on the controller.
The alarm level can be adjusted or turned o
ff
by entering the setup mode (
).
The zone which is currently ge
tti
ng setup will
fl
ash and will be highlighted by the
zone indica
ti
on arrow. You can move to setup the earth zone by pressing the
naviga
ti
on bu
tt
ons (< or >). Pressing (+ or -) increases or decreases the alarm level.
Increasing the earth alarm level reduces sensi
ti
vity. The earth alarm can be
disabled by pressing (-) un
ti
l the display shows (- -). To exit the setup mode wait
10 seconds or press the setup bu
tt
on (
).