HANDY HINT
Tes
ti
ng the earth system
Turn the energizer o
ff
. At least 40m (130
ft
) along the fence line drive a steel
a)
stake into damp soil and connect it to the fence wire.
Turn the energizer on and wait 30 seconds. Check the earth system voltage
b)
using the naviga
ti
on keys. The earth voltage should be 0.2 – 0.3KV or less. If
it is higher add earth stakes un
ti
l 0.2-0.3KV is achieved. In dry condi
ti
ons or
areas with low mineral content soil an earth return system may be required as
described in the Gallagher Power Fence™ Manual or go to www.gallagherams.
com.
Adjus
ti
ng the energizer output voltage
Press the setup bu
tt
on (
a)
) to enter setup mode and use the naviga
ti
on
bu
tt
ons ( < or >) to highlight the quickscan bargraph display (it will start
fl
ashing).
Press (+ or -) to adjust the output voltage up or down. The output voltage can
b)
be adjusted from 4.5KV to 8KV. The factory default se
tti
ng is 8KV.
To exit the setup mode wait 10 seconds or press the setup bu
tt
on (
c)
).
Controller showing the output voltage being adjusted