English
Gallagher 3E3084 M1800i M2800i 110v Energizer User Manual
5
INSTALLATION GUIDE
Energizer Controller
Mount the controller on a
fl
at surface within
3m (10 ) of the energizer, or up to 50m
(160 ) if using an RJ-12 extension cable
*
. The
controller is suitable for indoor and outdoor
use. Alterna vely, the bracket at the back of the
controller can be extended to allow it to stand
on a desk or bench.
a)
Remove the black bezel surround from the controller allowing access to the 4
moun ng holes in each corner. The 4 moun ng screws are located on the back
surface of the controller.
b)
Using the template on the back page as a drilling guide, drill 4 x 2.5mm (7/64”)
holes (A,B,C & D) at least 35mm (1.4”) deep.
c)
Fix the screws provided into the wall through the moun ng holes in each
corner. Place the black bezel on the controller.
d)
Route the controller cable to the energizer and plug it into the data connector
on the back cover.
Step 1. Install the Energizer
Mount the energizer on a wall, under cover
and out of reach of children. Install where
there is no risk of the energizer incurring
fi
re or
mechanical damage and if possible away from
heavy electrical equipment eg. pumps or other items that
may cause electrical interference.
a)
Using the template on the back page, drill 2 x 4mm
(5/32”) holes (E & F).
b)
Fix the screws provided into the wall leaving the head
of the screw about 3mm (1/8”) out from the wall.
c)
Place the energizer over and slide down onto the
moun ng screws.
d)
Remove orange terminal cover to expose Fence, Earth
and Reference Earth terminals.
*
To achieve greater distances up to 200m, a lower resistance cable is required.
b
a
Summary of Contents for M1800i
Page 27: ......
Page 28: ......
Page 30: ......
Page 51: ......
Page 52: ...www gallagher com Gallagher Private Bag 3026 Hamilton New Zealand...