English
Gallagher 3E4752 M5000i Energizer User Manual
20
Save these instruc ons
TROUBLESHOOTING
Problem
Causes
Solution
Energizer has started to
run slowly
The internal temperature of
the energizer is too high
Mount the energizer in a cool
area, out of direct sun and with
adequate ven la on
Displaying Error 11
Mains voltage is too high
Have your power supply
checked by a professional
electrician
Displaying Error 12
Mains voltage is too low
Have your power supply
checked by a professional
electrician
Displaying Error 14 - 19
or 22
Internal energizer fault
Turn energizer off for 30
seconds then turn back on. If
the error remains return the
energizer to your Gallagher
dealer for servicing.
Displaying Error 21
Dead zone
Check that the zone device
is connected and working
correctly.
Energizer output voltage
is low
There is a fault on the fence
Remove any excess grass
growth or short circuits on the
fence.
Earth voltage is too high
Earth system is inadequate
Check connec ons to the earth
system. Add extra earth stakes.
No output and display
shows ( - - )
Energizer is in standby mode Exit standby mode by pressing
the standby bu on on the
controller
WASTE ELECTRICAL AND ELECTRONIC
EQUIPMENT
This symbol on the product indicates that this product, packaging and with special
care of the ba ery must not be disposed of with other waste. Instead, it is your
responsibility to dispose of your waste equipment by handing it over to a designated
collec on point for the recycling of waste electrical and electronic equipment. The
separate collec on and recycling of your waste equipment at the me of disposal
will help conserve natural resources and ensure that it is recycled in a manner that
protects human health and the environment. For more informa on about where
you can drop off your waste equipment for recycling, please contact your local city
recycling offi
ce or the dealer from whom you purchased the product.