English
Gallagher 3E4345 MBS1000i MBS1800i MBS2800i Energizer User Manual
18
BATTERY GUIDE
The Energizer will automa cally reduce its power usage if the ba ery is star ng to
go
fl
at. This will be achieved by reducing the energy in each pulse and increasing the
interval between pulses.
Number of Pulses per minute
Ba ery Capacity
30
75% +
20
60 - 70%
15
50 - 60%
10
40 - 50%
6
20 - 40%
The Energizer stops pulsing if the ba ery drops below 20% to prevent damaging the
ba ery.
Gallagher Recommends:
•
Use 12 V deep cycle lead acid ba eries.
• Ba eries of the same type and manufacture can be connected in parallel to
increase capacity.
• Store
ba ery in a dry place between 0
o
C and 30
o
C.
•
Do not leave ba eries below 50% charge (12.0 V) for a prolonged period of
me.
• Ba eries must be in a well ven lated area while charging.
Ba ery Capacity
Required
Full Power Opera on (days)
MBS1000i
MBS1800i
MBS2800i
100 Ah
2
1.5
1
200 Ah
4
3
2
300 Ah
6
4.5
3
PRODUCT SPECIFICATIONS
MBS1000i
MBS1800i
MBS2800i
Power consump on
10 W powered by
15 V adapter
16.5 W powered by
15 V adapter
20 W powered by
15 V adapter
8 W powered by
12 V ba ery
11.5 W powered by
12 V ba ery
17 W powered by
12 V ba ery
Stored Energy:
10 J
18 J
28 J
Output Energy:
7.7 J
12.4 J
15.6 J
Output Voltage (no
load):
8 kV
8 kV
8 kV