13
TURNING THE STOVE TO PILOT
From any heat setting, depress control knob fully and turn clockwise to PILOT position. Disconnect.
TURNING THE STOVE OFF
From any heat setting or the PILOT position, depress control knob fully and turn clockwise to
OFF position.
REMOTE CONTROL STOVES
Once the fire is in place, connected, flued correctly, and the logs are in place, you can proceed with
lighting the stove and ensuring all the features are working correctly.
The fire control unit is located behind the right-hand foot of the stove.
The pilot light is located centrally at the rear of the burner.
Should the stove be extinguished for any reason wait 3 minutes before attempting re-ignition.
Connect a suitable pressure gauge to the inlet pressure test point to check the correct inlet pressures.
Fit AA batteries to the fire control unit. The control requires 3 AA size alkaline batteries to be inserted
under the battery compartment cover. The orientation of these is shown moulded into the battery
compartment.
After fitting the batteries and replacing the cover the fire can now be operated. Slide the Master switch
to the right to the ON position (I symbol). To start the fire, press the ON/OFF button and hold for 1
second then release. The burner will within around 1 to 10 seconds ignite and adjust to the maximum
power setting. This can take longer on the first lighting as it has to clear out any air locks.
Check that the supply pressure is 20 mbar ± 1 mbar.
The power of the burner can be adjusted up and down by pressing the + and – buttons.
Battery compartment cover opening lever
Battery compartment cover
Increase flame
Power Button
Decrease flame
White power isolator switch (sliding)
Indicator light
Summary of Contents for Classic Eco
Page 2: ...2...
Page 6: ...6 Dimensions GAS CLASSIC ECO STOVE...
Page 18: ...18 SERVICE AND MAINTENANCE LOG SERVICE DATE PERFORMED BY WORK PERFORMED...
Page 19: ...19 SERVICE DATE PERFORMED BY WORK PERFORMED...
Page 31: ...31...