SERVICING INSTRUCTIONS
The stove is fitted with a spillage monitoring system consisting of a thermal switch connected to a
thermocouple interrupter. This system is not adjustable and must not be put out of action. If any parts
of the spillage monitoring system require replacement only original manufacturer’s parts must be used.
The following servicing procedure should be carried out regularly and only by a qualified person.
•
Visually inspect the appliance for signs of spillage safe operation, check position as per
manufacturer’s instructions, including clearances and proximity to combustible materials
•
Ensure fixing is sufficient and the appliance is stable
• Check if gas pipe is sleeved through the wall and protected in accordance with BS6891
• Check the ventilation is correct
•
Ensure that the fire is turned off and is cold. Slacken the screw securing the door (Fig.1)
and open the door
• Remove the ceramics in the reverse order to that described in the POSITIONING THE LOGS
section (page 11). Due to the intense temperatures reached in the fire, some surface cracks may
appear on the ceramic components. This is quite normal and will not affect the safe operation of
the fire
•
Remove any remnants of dirt, lint etc. carefully from the burner flame strip, tray and pilot
assembly with a soft brush
• Replace the ceramics as described in POSITIONING THE LOGS section (Page 11)
• Check the internal combustion chamber for any signs of damage or paint failures (a high temp
paint can be used to rectify in these instances. Care must be taken not to contaminate the ignition
system or burner with paint overspray)
•
Ensure all the injector ports are clear and free from debris
(care must be taken not to damage these parts)
• Ensure the spark generator system is working correctly and the ignitor probe is intact
• Ensure the thermocouple tip is clean and free from any carbon build up
• Clean the glass taking care not to soak the rope with cleaning solution
• Check all rope and door seals for signs of deterioration (If damaged or worn in a way that appliance
has become unsafe then they must be replaced and the fire must be turned off and not be used until
such time that they are)
It is essential that the stove is regularly serviced, and the flue system checked by a qualified person. An
annual service is recommended as a minimum but not limited to.