background image

11 
 

Tertiary Air – not controlled (fixed supply) 

 
The Tertiary Air Supply is bled into the stove from the rear panel.  Its function is 
to ignite unburned gasses helping provide a clean burn.  It is advisable to clear 
these holes from time to time with a brush, especially when the stove is being 
serviced or after long periods of burning. 
ONLY  CARRY  OUT THIS AND ALL SERVICING PROCEDURES WHEN THE STOVE IS 
COLD.  This tertiary air supply is permanently open and allows a small amount of 
air  into  the  stove.    Operation  with  air  controls  open  can  cause  excess  smoke.  
These stoves must not be operated with air controls left open except as directed 
in these instructions. 

 
Lighting the Stove 

 
It  is  essential  that  you  have  three  or  four  small  fires  before  you  operate  the 
stove  to  its  maximum  heat  output.    This  is  to  allow  the  paint  to  cure  and  to 
“temper” your cast iron stove.  We recommend this ‘running-in’ procedure after 
long shutdowns to preserve the life of stove.  During the curing of the paint you 
may notice an unpleasant smell.  It is not toxic, but for your comfort we would 
suggest that during this period you leave doors and windows open. 
 
First,  load  the  fire  with  starting  fuel  i.e.  paper,  dry  kindling  timber  (about  the 
thickness of your thumb) and/or firelighters in the mode chosen, either wood or 
coal products.  

It is normal to see smoke come from the open stove door at this 

stage.

 

 
Light  the  fire  at  base  leaving  all  air  controls  open.    Allow  the  fuel  to  reach  a 
steady  glow  and  build  up  the  fire  gradually.    Once  you  have  a  good  fire 
established across the fire bed, further fuel can be added as required. 
 
When your fire is well established you can start to restrict the primary air intake.  
If you are burning only wood, the primary air control can be fully closed.  If you 
are burning solid fuel you will require  some primary air.  Your stove is burning 
with maximum efficiency when a bright fire is achieved using minimum air inlet 
and the Gallery Stove Thermometer (purchased separately) registers within the 
“Best Burn” range. 

 
 
 
 

Summary of Contents for HELIOS

Page 1: ...QUALIFIED AND COMPETENT INSTALLERS PLEASE LEAVE THIS BOOKLET WITH THE HOUSEHOLDER Gallery Stoves operate at very high temperatures All persons including children and the infirm should be warned of th...

Page 2: ...CONTENTS STOVE CONTROLS OUTPUT EFFICIENCY PAGE 03 COMPONENT PARTS PAGE 04 INSTALLATION PAGE 05 OPERATION PAGE 10 GENRAL MAINTENANCE PAGE 16 SAFETY NOTES TROUBLESHOOTING PAGE 18 STOVE ACCESSORIES PAGE...

Page 3: ...nmental Services in the Netherlands Variations may occur due to installation atmospheric conditions and fuel quality HELIOS 5 CB FUEL WOOD ANTHRACITE EFFICIENCY 82 8 83 4 FLUE GAS TEMPERATURE 224 C 21...

Page 4: ...use components made specifically for your stove ITEM DESCRIPTION ITEM DESCRIPTION 1 Stove body 8 Flue blanking plate 2 Hinge set 9 Primary air slide assembly 3 Door casting 10 Fuel retaining bar 4 Sid...

Page 5: ...OWED THIS APPLIANCE HAS BEEN EXTENSIVELY TESTED FOR SAFETY AND EFFICIENCY DO NOT ATTEMPT TO MODIFY IT ALWAYS USE GENUINE REPLACEMENT PARTS AS RECOMMENDED BY YOUR SUPPLIER FAILURE TO ADHERE TO THIS ADV...

Page 6: ...lean the appliance flue ways flue pipe and chimney prior to lighting up after a prolonged shut down period Check the chimney is in good condition dry and free of cracks leaks and obstructions The diam...

Page 7: ...that it should be swept every twelve months thereafter If used regularly it is recommended that your chimney is swept every six months An existing fireplace opening can be modified to accommodate the...

Page 8: ...a stainless steel flexible liner for solid fuel if your chimney is larger than 230mm x 230mm A closure plate with access for cleaning may also be required together with a short length of flue pipe of...

Page 9: ...ures of up to 200o C Hearths Allow an apron of at least 225mm at the front of the stove and 150mm on either side Care should be taken to level the stove and secure the hearth If existing floors do not...

Page 10: ...EN THE STOVE DOOR SLOWLY AND ALWAYS USE THE GLOVE Primary Air controllable Primary air is controlled via the sliding vent in the bottom of the door This provides an air draught through the grate to th...

Page 11: ...long shutdowns to preserve the life of stove During the curing of the paint you may notice an unpleasant smell It is not toxic but for your comfort we would suggest that during this period you leave...

Page 12: ...ood draft and stove settings so please do experiment to find your own best settings and the best position on your Stove Thermometer Other Solid Fuel Burning Always clean out the ash pan before refuell...

Page 13: ...o dimension is greater than 3 75mm it would take about 3 years to dry A dry log will produce up to four and a half times more heat output than a freshly cut log Wet logs take heat to dry Other Solid F...

Page 14: ...as have been authorised and that appliances used to burn solid fuel in those areas other than authorised fuels have been exempted for each area of administration Further information on the requirement...

Page 15: ...plate drops down from the rear fire brick that it was resting upon The plate can now be withdrawn through the open doorway of the stove To replace place the baffle plate inside the stove in the corre...

Page 16: ...Stove Paint available from your supplier Glass Panels Clean the glass panels when cool with Gallery Glass Cleaner Highly abrasive substances should be avoided as these can scratch the glass and make...

Page 17: ...and maintenance of the appliance and chimney system Fires Can Be Dangerous Always use a fire guard to BS 8423 2002 Fireguards for Use With Solid Fuel Appliances in the presence of children the elderl...

Page 18: ...cause has been identified and corrected If necessary seek professional advice These situations are very dangerous and must NOT be tolerated A list of Qualified Engineers is available from UK Solid Fue...

Page 19: ...vary in heat value check with your coal merchant as to suitability Dirty Glass Nearly always caused by poor fuel quality check the moisture content of the wood you are burning with a Gallery moisture...

Page 20: ...phite high temperature paint Stove Glass Cleaner Spare Rope Rope Seal Adhesive CO Detector Gallery Stove Fan Gallery Stove Thermometer Wood Moisture Meter Spare Glove Permanent Ventilators Purpose bui...

Page 21: ...21 Brought to you by Percy Doughty Co Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN 01204 868 550 www percydoughty com...