2. Installation
2. Installation
Warning! Aluminium collectors must be connected to the installation by stainless steel
pipes. In addition, aluminium collectors use chrome connection sets, as well as special
glycol type, intended for aluminium collectors only.
2.1. Connection kit
The connection kit includes:
Part
pcs.
Remarks
X-piece on clamp Ø22 mm x 1/2”GW x 1/2”GW x 3/4”GZ with submersion sleeve
and mechanical vent
1
-
Bend on clamp Ø22 mm x 3/4” GZ
1
-
Double-clamp coupling Ø22 mm x Ø22 mm
1
Applies to sets with two flat solar collector of a Premium
type, as well as tube collectors - type KSG PT. Each additional
collector (above 2) requires an additional coupling.
When using the stainless steel, flexible pipes - FLEX in the installation, it is recommended to use a self-inflating station for venting and filling
the installation. When venting and filling the installation manually aeration may frequently occur.
2.2. Connecting the KSG21/27 Premium GT, KSG21/27 GT and KSG PT15, KSG PT20 collectors
Connection kit for 2 collectors.
CONSTANS
45-50 Nm
Warning!
Tighten the compression
fittings with a force of
45-50 Nm
.
While tightening, the
coupler should be
stabilized with an
additional counter key
.
Failure to do so may cause
damage to the collector
!
Exemplary mounting of the connection kit for Galmet's solar collectors