4. Technical specification
4.10. Technical parameters - SG(B) 200 with one spiral coil
Type SG(B)
unit
SG(B) 200
Storage capacity
*
l
212
Tank’s maximum working temperature
°C
95
Tank’s maximum working pressure
bar
3
Coil's maximum working pressure
bar
6
Coil's surface
m
2
1,4
Dimensions
CH boiler water connection height
GS1 mm
220
Sensor cover or thermometer connection height GS2 mm
312
CH boiler water connection height
GS3 mm
483
Sensor cover or thermometer connection height GS4 mm
603
CH boiler water connection height
GS5 mm
785
Sensor cover or thermometer connection height GS6 mm
885
CH boiler water connection height
GS7 mm
220
Coil return connection height
GS8 mm
220
CH boiler water connection height
GS9 mm
553
Coil feeding connection height
GS10 mm
690
Sensor cover or thermometer connection height GS11 mm
785
CH boiler water connection height
GS12 mm
885
Height
L
mm
1105
External diameter (without insulation)
d
Ø
550
External diameter (with insulation)
D
Ø
670
Insulation
mm
55
External housing
-
skay
Connections
CH boiler water inflow / CH boiler water outflow
Gw
1 ½"
Sensor cover or thermometer
Gw
½"
Coil feeding / Coil return
Gw
1"
Water drain
Gw
1"
Weight without insulation (empty)
kg
440
*
Tank's capacity without spiral coils.