5. Technical specification
5.3. Technical specification of the SGW(S) Maxi water heaters 700, 1000
Specification
Unit
SGW(S) Maxi 700
SGW(S) Maxi 1000
Heating coil
-
CH / heat pump
CH / heat pump
Storage capacity
1
l
657
973
Maximum allowable temperature
°C
100
100
Maximum working pressure
bar
10
10
Coil surface
m
2
6,5
6,5
Coil capacity
l
45,4
45,4
Demand for heating water from CH boiler
m
3
/h
3
3
Coil power (80/10/45°C)
kW
138
138
Coil power (80/10/60°C)
kW
108
108
Coil power (50/10/45°C)
kW
39
39
Demand for heating water
m
3
/h
3
3
Dimensions
h1 - Cold water inflow height
mm
215
245
h2 -CH water outflow height
mm
395
445
h3 - Sensor cover height
mm
755
745
h4 - CH hot water inflow height
mm
1175
1075
h5 - Circulation height
mm
1355
1195
h6 - DHW outflow
mm
1715
1565
L - Device height
mm
2060
1960
d - Tank diameter (without insulation)
Ø
700
900
D - Diameter (including insulation)
Ø
855
1055
Insulation made of hard polyurethane foam
mm
70
70
External enclosure
-
PVC film
Hydraulic connections
Cold water / hot water
Gw
6/4"
6/4"
Circulation
Gw
5/4"
5/4"
CH circuit / heat pump (supply / return)
Gw
5/4"
5/4"
Flange
Ø
280/205
280/205
Sensor cover
R
3/8"
3/8"
Thermometer
Gw
1/2"
1/2"
Magnesium anode
An.
2"
2"
Weight (empty)
kg
350
530