1.Function of the storage tanks
Storage tanks are used for accumulating spare heat from its source.
Source can be:
- central heater on solid fuel
- solar system
- fireplace stoves with exchangers
- heat pump system.
- electric heater (for external tank) etc.
Some storage tanks enable combining more sources of energy. The vessel inside
wall covered with ceramic enamel, external tank not enamelled. Storage tanks are
insulated with ecological hard polyurethane faom which reduces heat loss to the
absolute minimum. It is placed in internal tank on plug 5/4 " magnesium anode (it look
drawing of number 1, 2)
2. Technical data
3. Installation of the storage tanks
The heater has to be installed by a fitter with relevant license. Heater installation needs to be
recorded on he guarantee card. Because of its construction, the heater can be assembled only
VERTICALLY. Connect the internal tank (with possibility of disconnection e.g. for maintenance)
directly to the water supply system with pressure not more than 0.6 MPa; the minimum pressure
cannot be lower than 0.1 MPa - ca. 1 bar). If the pressure in the water supply system is more than
0.6 MPa, it is necessary to reduce it by application of a pressure reducing valve.
-11-
TYPE:
300/80
380/120
500/160
600/200
800/200
1000/200
Capacity tank for demineralised water
l
220
260
340
400
600
800
Capacity tank for H.C.W.
l
80
120
160
200
200
200
Circulation water pressure
MPa
0,3
System water pressure
MPa
0,6
Max. heating water temp. in the tank
°C
90
Max. heating water temp. in the
exchanger
°C
100
Solar coil surface
m
2
1,6
2,1
2,1
2,1
2,4
2,4
C/H exchenger surface
m
2
0,9
1,2
1,2
1,2
1,2
1,5
External diameter
ØD
710
710
850
850
1050
1050
Total height
L
1480
1890
1750
1950
1750
2000
Net weight
kg
165
220
255
295
485
525