background image

Included in this Kit:
(1) RFR12V1PR-LS Receiver
(1) 3-Button Transmitter 

*Image shown with standard transmitter*

Available accessories:
- Additional Transmitter KF340-3 
- Waterproof Transmitter KF340-3L-WP

- Long Range Antenna LRA340 

**SEE PAGE 3 FOR SETUP**

- 6-Pack of Replacement A-23 12V Batteries A23-6

Overview

The RF12V1PR-LS is an RF receiver operating at a fixed frequency of 340 MHz. The receiver operates from 12-Volts DC and 
provides a polarity reversing output.  The polarity reversing output incorporates current sensing that will monitor the output current 
and turn off the output when the operating current exceeds the current setting of the switch.  Limit switch inputs are included that will 
interrupt the output when the limit switch is contacted.   The receiver includes two inputs that are used with a manual switch to 
control the polarity reversing output.  The receiver also has a 12-Volt light output.   

The transmitter has 3-switches, two for the control of the polarity reversing output and one to activate the light output.  The receiver 
can be configured to operate the output in momentary or latching mode.  Up to thirty, three-button transmitters (model KF340-3) can 
be used to activate the receiver's output.  Each transmitter has a unique address that is transmitted when a button is pressed.  A 
"program" button is provided on the receiver to program the transmitter(s) address into the receiver's memory.  An LED on the 
receiver indicates the receiver's programming status and illuminates when either relay is energized.

The receiver includes inputs for manual control of the polarity reversing output.  The inputs are labeled “UP Manual” and “Down 
Manual”.  

The receiver electronics are encapsulated in a 5” x 5” x 1” mounting tray. The operating range is at least 100 feet.  

Maximum Ratings:

 Power for the receiver can be in the range of 10 to 15Vdc. The receiver is reverse polarity protected.  The relay 

contacts are rated at 35 Amps @ 13.8Vdc.
 

Power Consumption:

  10mA when the relays are de-energized, 45mA when the relay is energized.

Input Power Connection:

  12Vdc power connects to the 

+12V

 and 

GND

 terminals.

Output Connection:

  The output of the receiver is connected to the terminals labeled “

To Motor

”.

Page 1 REV B 02/25/21

WWW.GAMAINC.COM

RF12V1PR-LS

Instruction Manual

Summary of Contents for RF12V1PR-LS

Page 1: ...The receiver can be configured to operate the output in momentary or latching mode Up to thirty three button transmitters model KF340 3 can be used to activate the receiver s output Each transmitter has a unique address that is transmitted when a button is pressed A program button is provided on the receiver to program the transmitter s address into the receiver s memory An LED on the receiver ind...

Page 2: ...ure the receiver for momentary output press and release the UP button once on the transmitter and verify that the red program LED extinguishes and then illuminates blinks once Proceed to Step 5 4 To configure the receiver for latching output press and release the UP button on the transmitter twice and verify that the red program LED extinguishes and illuminates several times blinks rapidly 5 To ad...

Page 3: ...ater than 500 feet If the long range option is purchased with the system this modification will be made prior to shipment NOTE ONCE THE LONG RANGE MODIFICATIONS HAVE BEEN MADE TO THE SYSTEM THEY CANNOT BE REVERSED To add long range functionality 1 Plug long range antenna Part number LRA 340 into the long range antenna jack 2 Clip the Long Range Antenna Bypass Wire This will deactivate the internal...

Page 4: ...n the remote control or the manual switch NOTE IF LIMIT SWITCHES ARE NOT USED FOR ONE OR BOTH DIRECTIONS YOU MUST SUPPLY A CONSTANT 12VDC SIGNAL TO THE LIMIT UP OR LIMIT DOWN POSITION ON THE TERMINAL BLOCK FOR THE MOTOR OUTPUT TO FUNCTION Manual Switch Inputs The receiver includes inputs for a manual switch to control the polarity reversing output The manual control inputs to the receiver are labe...

Page 5: ...sensing is adjustable from 5 Amperes to 35 Amperes There is a 0 5 second delay in the current sensing to allow for motor inrush 1 2 3 4 5 6 7 0 8 9 A B C D E F The recess down the length of the shaft points to the setting SWITCH SETTING 0 1 2 3 4 5 6 7 8 9 A B C D E F CURRENT LIMIT 5 AMPS 7 AMPS 9 AMPS 11 AMPS 13 AMPS 15 AMPS 17 AMPS 19 AMPS 21 AMPS 23 AMPS 25 AMPS 27 AMPS 29 AMPS 31 AMPS 33 AMPS ...

Page 6: ...reprogram the remote control The program may not have taken during the programming process or the program button may have been pressed If the program button is pressed the memory of the remote controls programed to the receiver are erased 4 Listen and look for functionality on the receiver The LED that is used for programming the system will illuminate when the receiver is activated You will also ...

Reviews: