Included in this Kit:
(1) RFR12V1PR-LS Receiver
(1) 3-Button Transmitter
*Image shown with standard transmitter*
Available accessories:
- Additional Transmitter KF340-3
- Waterproof Transmitter KF340-3L-WP
- Long Range Antenna LRA340
**SEE PAGE 3 FOR SETUP**
- 6-Pack of Replacement A-23 12V Batteries A23-6
Overview
:
The RF12V1PR-LS is an RF receiver operating at a fixed frequency of 340 MHz. The receiver operates from 12-Volts DC and
provides a polarity reversing output. The polarity reversing output incorporates current sensing that will monitor the output current
and turn off the output when the operating current exceeds the current setting of the switch. Limit switch inputs are included that will
interrupt the output when the limit switch is contacted. The receiver includes two inputs that are used with a manual switch to
control the polarity reversing output. The receiver also has a 12-Volt light output.
The transmitter has 3-switches, two for the control of the polarity reversing output and one to activate the light output. The receiver
can be configured to operate the output in momentary or latching mode. Up to thirty, three-button transmitters (model KF340-3) can
be used to activate the receiver's output. Each transmitter has a unique address that is transmitted when a button is pressed. A
"program" button is provided on the receiver to program the transmitter(s) address into the receiver's memory. An LED on the
receiver indicates the receiver's programming status and illuminates when either relay is energized.
The receiver includes inputs for manual control of the polarity reversing output. The inputs are labeled “UP Manual” and “Down
Manual”.
The receiver electronics are encapsulated in a 5” x 5” x 1” mounting tray. The operating range is at least 100 feet.
Maximum Ratings:
Power for the receiver can be in the range of 10 to 15Vdc. The receiver is reverse polarity protected. The relay
contacts are rated at 35 Amps @ 13.8Vdc.
Power Consumption:
10mA when the relays are de-energized, 45mA when the relay is energized.
Input Power Connection:
12Vdc power connects to the
+12V
and
GND
terminals.
Output Connection:
The output of the receiver is connected to the terminals labeled “
To Motor
”.
Page 1 REV B 02/25/21
WWW.GAMAINC.COM
RF12V1PR-LS
Instruction Manual