evolution G-50 H
Service Manual
13/48
Issue 3.2
For the data input, the order will be as follows:
•
Temperature set-point for A(ISO) heater and B or R (POL).
•
Temperature set-point for A(ISO) hose and B or R (POL).
•
Amps set-point for A (ISO) and B or R (POL).
•
Ratio adjustment.
•
Cycles pre-selection.
•
Date input
If the TCS stops working, the temperature display will show the symbol
(---)
and the heating will
be automatically turned off.
AT start-up, the hose heat set point is not maintained in memory and must be reset after each
activation of the CONTROL POWER key.
To select the hose power when the unit is working in manual heating control mode, press the
MODE key until the amperage flashes
,
press the UP / DOWN keys to enter the number of amps
required and press the MODE key once more
to enter the value into memory.
Refer to the table shown below to select the power that is required to reach the application
temperature:
30 A
38º C 100º F
35 A
48º C 118º F
40 A
60º C 140º F
45 A
75º C 167º F
50 A
80º C 176º F
Select the required amps for a quick pre-heating.
NOTA:
The circuit breaker software of the transformer has a safety system to prevent the hoses
from being exposed to high temperatures during long periods of time.
If you have selected a potential over 35 amperes, after 20 minutes, the potential will
automatically regulate to 35 amperes.
This potential cannot be set above 35 amperes until the heater is disconnected from the
hoses and reconnected.
The settings programmed by the machine operator will be stored for the next time the
heating is switched on.