evolution G-50 H
Service Manual
11/48
Issue 3.2
Figure 2
. Control Panel
The Control Panel allows the optimum working conditions to be selected and set, depending on
the characteristics and requirements of the products to be dispensed. Using the MODE key, the
different control parameters may be entered. The parameter display will flash for a few seconds
to allow the change of this value by pressing the UP / DOWN keys. Once the change is made,
press the MODE key once more for the new value to be entered into memory and to select the
next parameter for setting.
The modification mode will be interrupted automatically after 3 seconds without activity on the
keyboard.
The parameters that may be selected and displayed are the following:
•
Hose temperature in automatic control mode (maximum 80º C / 176º F)
•
Hose heating power (maximum 50 Amps)
•
Isocyanate heater temperature (maximum 90ºC / 194º F)
•
Polyol heater temperature (maximum 90ºC / 194º F)
•
Total number of cycles to be made
•
Number of cycles made
CONTROL PANEL