Parts Identification
& Manual Service
8/40
Issue 1.0
•
Attach and airless spray gun to the spray hose. Do not attach the tip to the spray gun
yet. Remove the tip if it is already attached.
•
Check the hydraulic fluid level daily before starting the unit. The hydraulic fluid level
should be at the “Full” mark, on the dipstick.
•
For gas models, check the engine oil level daily before starting the unit. The gasoline
engine oil level is determined by the engine manufacturer.
•
Place the suction pipe into a container of solvent/water.
•
Place the bleed hose into a metal waste container.
•
Set the pressure to minimum by turning the pressure control knob fully counter
clockwise.
•
Open the hydraulic shut-off valve located on the hydraulic pressure hose. The handle
should be in line with the hose.
•
Open the bleed valve by turning it fully counter clockwise.
•
Start the engine or turn on the electric motor.
a) To start the gas engine:
Move the fuel valve lever to the open position.
Move the throttle lever to its middle point.
Move the choke lever to the closed position for a cold engine or to the open
position for a warm engine.
Turn the engine switch to the ON position.
Pull the starter rope briskly until the engine starts.
b) To start the electric motor, move the ON/OFF switch to the ON position.
•
Turn the pressure control knob clockwise approximately 1/3 of the way down to
increase pressure until the sprayer cycles evenly and solvent flows freely from the bleed
hose.
•
Allow the sprayer to run for 15-30 seconds to flush the test fluid out through the bleed
hose and into the waste container.
•
Turn off the unit
a) To turn off the gas engine:
Set the pressure to minimum by turning the pressure control knob fully counter
clockwise.
Move the throttle lever to the slow position.
Turn the engine switch to the OFF position
b) To turn off the electric motor:
Set the pressure to minimum by turning the pressure control knob fully counter
clockwise.
Move the ON/OFF switch to the OFF position.
OPERATION