PRECAUTION:
When working with the gun or doing maintenance on it, all suitable
protection must be used in accordance with the recommendations and specifications
given by the product suppliers.
HI-TECH
provides a series of tools and accessories which are necessary for assembling the
gun. The unit comprises the following elements:
Tube spanner, chuck, grease tube, nozzle stopper, greaser stopper, air connection pipe, fast
plug, tracks for cleaning, operations manual and components manual.
1.
Completely close the manual valves by turning them clockwise. The manual valves control
the input flow of each product to the chamber and are located on the Coupling Block.
2.
Connect the air supply pipe to the connector at the rear of the gun.
3.
Connect the Isocyanate hose (red terminal) to the Isocyanate input connector (letter A) on
the Coupling Block.
4.
Connect the Polyol hose (blue terminal) to the Polyol input connector (letter R) on the
Coupling Block.
NOTE:
The product hoses
have been distinguished
with red and blue in order
to allow them to be rapidly
identified.
The
red
corresponds
to
the
Isocyanate hose and the
blue corresponds to the
Polyol hose. To avoid
connection
errors,
the
Isocyanate
and
Polyol
hose coupling connectors
are
of
different
sizes,
which makes it impossible
for
connections
to
be
swapped.
INSTALLATION AND START-UP