G-NET 19” UPS User Manual

 

 

iv

 

 

S

AFETY 

P

RECAUTIONS

 

The UPS system is designed for industrial applications and harsh environments. Nevertheless 
the  UPS is a sophisticated power system and should be handled with appropriate care, 
according to the following guidelines.  
 

WARNING!  HIGH TOUCH CURRENT! 

EARTH CONNECTION ESSENTIAL BEFORE CONNECTING SUPPLY. 

D

O

S

 

 

Read this manual carefully before starting installation and operation of the UPS. 

 

Review the safety precautions described below to avoid injury to users and damage to the 
equipment. 

 

All power connections must be completed by a 

licensed electrician who is experienced in 

wiring this type of equipment,

 and who is 

familiar with the local electrical codes and 

regulations.

 

Improper wiring may cause injury to personnel, or death, 

or damage to the 

equipment

 

Ensure all power is disconnected before performing installation or maintenance.

 

 

Leave at least 20 cm of clearance space between the ventilation openings of the UPS and other 
objects or walls. 

 

The UPS must be well grounded to the building’s grounding system with a conductor that has a 
current carrying capacity that matches the rating of the UPS. 

 

Battery installation, battery maintenance, and battery replacement shall be performed only by 
authorized service personnel. 

 

Pay attention to all DANGER, CAUTION, and WARNING notices affixed to the inside and 
outside of the UPS.  

 

Keep the surroundings clean, uncluttered and free from excess moisture. 

 

Keep the operating environment within the parameters stated in this document. 

 

Allow only qualified technicians to service the UPS. There are no user-serviceable components. 

Do not try to repair it yourself! 

 

Use the UPS only for its intended purpose.

 

 

The batteries should preferably be installed next to the UPS, or as close to it as is practically 
possible.

 

 

 

WARNING - RISK OF LETHAL ELECTRIC SHOCK: 

The battery cabinet contains a series of batteries that provides high voltage and energy in 
the UPS body even when the UPS is not connected to the ac input.  
Take appropriate precautions during installation, inspection and servicing.

 

 

Summary of Contents for g-net 101010002U-SD

Page 1: ...gamatronic com G G N NE ET T 1 1 K KV VA A 2 2 K KV VA A 3 3 K KV VA A O ON NL LI IN NE E U UN NI IN NT TE ER RR RU UP PT TI IB BL LE E P PO OW WE ER R S SY YS ST TE EM M 1 19 9 r ra ac ck k m mo ou...

Page 2: ...and for any damages that the Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the subject product This...

Page 3: ...TENANCE 9 7 SERVICE AND REPAIRS 9 8 TECHNICAL SPECIFICATIONS 10 LIST OF FIGURES Figure 1 Block diagram of system architecture 2 Figure 2 The UPS front panel 3 Figure 3 Rear panel of 1 kVA unit 4 Figur...

Page 4: ...space between the ventilation openings of the UPS and other objects or walls The UPS must be well grounded to the building s grounding system with a conductor that has a current carrying capacity that...

Page 5: ...o not move the UPS while it is operating Do not use the UPS outdoors Do not turn the UPS upside down during transportation Do not connect or disconnect the cable to the battery cabinet before the batt...

Page 6: ...GAMATRONIC ELECTRONIC INDUSTRIES LTD G NET 19 UPS User Manual vi...

Page 7: ...he model name is printed on the G Net s rear panel 1000 VA 2000 VA or 3000 VA If you are unpacking the G Net in a low temperature area some condensation may occur on the outside or inside of the UPS I...

Page 8: ...nuously provides conditioned power to attached devices Under normal power conditions the UPS is constantly regulating and filtering out any fluctuations of the input voltage In the event of an electri...

Page 9: ...d by the UPS Vac 2 Output voltage as measured by the UPS Vac 3 Output frequency as measured by the UPS Hz 4 Load level as a percentage of a full load 5 Remaining battery capacity as a percentage of a...

Page 10: ...cy Power Off EPO button 7 Connection point for external battery 8 Fan grille 9 D9 connection for RS232 communication Figure 4 Rear panel of 2 kVA and 3 kVA models Table 3 Key to Figure 4 ITEM DESCRIPT...

Page 11: ...GAMATRONIC ELECTRONIC INDUSTRIES LTD G NET 19 UPS User Manual System description 5 Figure 5 Backup time vs load representative...

Page 12: ...rt on the G Net rear panel 4 The other end of the battery cable has three branches Connect the red branch of the battery cable to the plus terminal of the battery box Connect the black branch of the b...

Page 13: ...tch OFF the G Net press the OFF button on the front panel for 2 or 3 seconds 3 3 3 Performing a battery test To test the UPS battery when the UPS and the load devices connected to it are operating do...

Page 14: ...the computer The D9 socket is shaped like this 2 Insert the supplied compact disk into the computer The installation program on the disk begins execution automatically Follow the instructions on the c...

Page 15: ...tee period Gamatronic bears no liability for damage caused to the UPS due to improper maintenance by third parties in particular after the expiration of the warrantee or service agreement It is the re...

Page 16: ...load 6 Overload tolerance 105 130 moves to bypass after 30 sec over 130 moves to bypass after 200 ms Ratio max normal load crest ratio 3 1 Transfer times msec To from battery To from bypass typical m...

Page 17: ...o Dc Converters Frequency Changers Battery Chargers Power Management Solutions Headquarters and Factory 17 Professor Hartum Street POB 45029 Jerusalem 9777517 Israel Gamatronic UK Ltd 15 Chester Road...

Reviews: