30
Interference
Attention!
Always remove the plug from the socket when carrying out repairs!
The cabinet does not start.
• Check the plug.
• Restore the power supply by replacing a fault fuse or by using the on/off switch.
• Contact your local service organization.
Temperature is too high, in spite of recent adjustment of thermostat.
• Check/restore power supply.
• Remove contents which may obstruct ventilation.
• Clean magnetic seal, replace if necessary. Remove contents which may obstruct ventilation
• Defrost evaporator.
• Thermostat or compressor is defect.
• Fan (evaporator or condenser) is defect.
• Contact your local service organization.
Temperature is too low, in spite of recent adjustment of thermostat.
• Thermostat is defect.
• Contact your local service organization.
Water leak
• Defrost regularly - if necessary extra manual defrost cycle.
• Check if the product is leveled. If necessary level the product.
• Contact your local service organization.
Plug lead
• To prevent accidents the plug lead, if damaged, may only be replaced by the service/maintenance
organization or qualified installer.