background image

 

- 4 -

There are two ways for clearing the input value: 
3.7.1 You can directly press SETEUP CLEAR to clear the value you have just 
input.  
3.7.2 Input new value in five seconds after the last value is input and the original 
setup will automatically be changed. 
          Note: After inputting the digits, you should press the corresponding key as 
FIXED NUMBER CALL, UNIT WEIGHT SET, COUNT SET or SET UP CLEAR 
to confirm, or all the key operation will not he effective. 
 

3.8 Operation concerned accumulation 

3.8.1 This counting scale has the latest preventing fraud function (i.e. the display 
must return to zero after an accumulation and before going to next accumulation). 
Under the situation that the unit weight is set or when the unit weight is sampled, 
when 0 is displayed in the weight window, place the goods weighed on the 
platform. 
        After awaiting the weight to be stable and the "STA" to be on or corresponding 
unit cursor appears, press "+", the accumulative total count will be displayed in its 
count window. When the count is more than 99999, FULL will be displayed. Three 
seconds later, it will return to normal weighing state and the current accumulation is 
not effective. 
3.8.2 Accumulation display: Press TOTAL DISPLAY, the weight window displays 
TOTAL will be displayed, and the unit weight window displays the accumulating 
times and the accumulated count "XXXXX" will be displayed in its count window, 
if press TOTAL DISPLAY again, it will return to normal weighing state. 
3.8.3 Accumulation clearing (including times and value) 
Under normal counting state, press TOTAL DISPLAY, and then press MEMORY 
CLEAR. ADD will be off or   
‘M+’ cursor disappears, at this moment the accumulated times and count will be 
cleared.  
     Note: The accumulating value and times will be automatically cleared when it 
is turned off. 
 

4. RS-232C Output (optional) 

 
4.1 RS-232C interface adopts the D-type 9-pin or 3-core metal plug. 
4.2. Serial data (ASC II) is output by Mode I of MCS-51, the format is as the 
following: 
STX: State A / State B / State C / Display value / Tare value / Total number / Enter   
STX: Start character, 02H 
State A: Control character for decimal point (D7 refers to verification bit) 
D7 D6 D5 D4 D3 D2 IA  DO Decimal 

point 

position 

  0 1 0 1 0 1 0 Without 

decimal 

point 